TE Connectivity Raychem Cable Protection | 1.5 mm | 0.6 mm | 0.024 in | 0.059 in | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29.5 mm | Filtered (EMI RFI) - Commercial | 4 A | Panel Mount Snap-In | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | 1.5 mm | 0.6 mm | 0.024 in | 0.059 in | | | Wire Leads | IP40 | | 33 mm | 29.5 mm | Filtered (EMI RFI) - Commercial | 2 A | Panel Mount Snap-In | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-0 | Fuse Holder Twin Fused | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | | | | | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29 mm | Filtered (EMI RFI) - Commercial | 10 A | Flange Panel Mount | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | 1.5 mm | 0.6 mm | 0.024 in | 0.059 in | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29.5 mm | Filtered (EMI RFI) - Commercial | 2 A | Panel Mount Snap-In | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | | | | | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29 mm | Filtered (EMI RFI) - Commercial | 10 A | Flange Panel Mount | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | | | | | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29 mm | Filtered (EMI RFI) - Commercial | 1 A | Flange Panel Mount | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder Twin Fused | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | 1.5 mm | 0.6 mm | 0.024 in | 0.059 in | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29.5 mm | Filtered (EMI RFI) - Commercial | 1 A | Panel Mount Snap-In | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | 2.5 mm | 1.6 mm | 0.063 in | 0.098 in | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29.5 mm | Filtered (EMI RFI) - Commercial | 4 A | Panel Mount Snap-In | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | 1.5 mm | 0.6 mm | 0.024 in | 0.059 in | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29.5 mm | Filtered (EMI RFI) - Commercial Medical | 2 A | Panel Mount Snap-In | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder Twin Fused | CQC CSA ENEC UL |
TE Connectivity Raychem Cable Protection | 1.5 mm | 0.6 mm | 0.024 in | 0.059 in | 0.25 in | 6.3 mm | Quick Connect | IP40 | | 33 mm | 29.5 mm | Filtered (EMI RFI) - Commercial | 6 A | Panel Mount Snap-In | Receptacle Male Blades - Module | IEC 320-C14 | UL94 V-2 | Fuse Holder | CQC CSA ENEC UL |