VMS-450 Series
Manufacturer: CUI Inc.
AC/DC POWER SUPPLY SINGLE-OUT 54V 8.3A 450W 17-PIN BOX
| Part | Mounting Type | Voltage - Output 1 | Type | Standard Number | Features | Voltage - Isolation | Applications | Power (Watts) | Voltage - Input (AC) Maximum | Voltage - Input (AC) Minimum | Current - Output 1 | Operating Temperature (Max) | Operating Temperature (Min) | Size / Dimension Width | Size / Dimension Height | Size / Dimension Length | Number of Outputs | Efficiency | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CUI Inc. | Chassis Mount | 54 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 448 W | 240 VAC | 100 VAC | 8.3 A | 70 °C | -20 °C | 3.15 in | 1.6 in | 5.83 in | 1 | 92 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 19 V | Open Frame | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 450 W | 240 VAC | 100 VAC | 23.7 A | 70 °C | -20 °C | 3 in | 1.26 in | 5 in | 1 | 92 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 48 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 451 W | 240 VAC | 100 VAC | 9.4 A | 70 °C | -20 °C | 3.41 in | 1.97 in | 5 in | 1 | 91 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 12 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 450 W | 240 VAC | 100 VAC | 37.5 A | 70 °C | -20 °C | 3.41 in | 1.97 in | 5 in | 1 | 89 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 48 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 451 W | 240 VAC | 100 VAC | 9.4 A | 70 °C | -20 °C | 3.41 in | 1.97 in | 5 in | 1 | 91 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 12 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 450 W | 240 VAC | 100 VAC | 37.5 A | 70 °C | -20 °C | 3.41 in | 1.97 in | 5 in | 1 | 89 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 24 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 451 W | 240 VAC | 100 VAC | 18.8 A | 70 °C | -20 °C | 3.41 in | 1.97 in | 5 in | 1 | 91 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 12 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 450 W | 240 VAC | 100 VAC | 37.5 A | 70 °C | -20 °C | 3.15 in | 1.6 in | 5.83 in | 1 | 89 % | CB Scheme EN IEC TUV UL |
CUI Inc. | Chassis Mount | 15 V | Enclosed | 55011 Class B 60601-1 61000-3-2 61000-3-3 | PFC Remote On/Off Standby Output Universal Input | 4000 Vpk | Medical | 450 W | 240 VAC | 100 VAC | 30 A | 70 °C | -20 °C | 3.15 in | 1.6 in | 5.83 in | 1 | 89 % | CB Scheme EN IEC TUV UL |