PartMounting TypePackage / CaseSupplier Device PackageNumber of ChannelsVoltage - Supply, Digital [Min]Voltage - Supply, Digital [Max]Voltage - Supply, Analog [Max]Voltage - Supply, Analog [Min]Number of BitsTypeUtilized IC / PartSupplied ContentsFunction
Texas Instruments
OPT3101RHFR
Surface Mount
28-VFQFN Exposed Pad
28-VQFN (5x4)
3
1.7 V
1.9 V
1.9 V, 3.6 V
1.7 V, 3 V
16 bits
Texas Instruments
OPT3101EVM
Interface
OPT3101
Board(s)
Analog Front End (AFE)
Texas Instruments
OPT3101RHFT
Surface Mount
28-VFQFN Exposed Pad
28-VQFN (5x4)
3
1.7 V
3.6 V
3.6 V
1.7 V
16 bits

Key Features

Long-Range Distance Measurement, Obstacle Detection and AvoidanceFlexibility to Customize Design With a Wide Variety of Photodiodes and EmittersSample Rate up to 4 kHz16-Bit Distance Output at 15-m Unambiguous RangeDe-Aliasing to Extend the Distance RangeSupports 3 Transmitter Channels for Multi-Zone OperationExcellent Ambient and Sunlight Rejection200-nA Full-Scale Signal Current88-dB Signal Phase Dynamic Range at 1 kHzSupports DC Ambient up to 200 µA, 60-dB Rejection for Ambient at 1 kHzDistance Measurement Independent of Object ReflectivityAdaptive HDR to Save Power and Increase the Dynamic RangeConfigurable Event Detection and Interrupt Output MechanismI2C Interface for Control and DataIntegrated Illumination Driver With Programmable Current Control up to 173 mAIntegrated Temperature Sensor for CalibrationSingle 3.3-V or 1.8-V and 3.3-V Supply OperationOperating Ambient Temperature: –40 to 85°CLong-Range Distance Measurement, Obstacle Detection and AvoidanceFlexibility to Customize Design With a Wide Variety of Photodiodes and EmittersSample Rate up to 4 kHz16-Bit Distance Output at 15-m Unambiguous RangeDe-Aliasing to Extend the Distance RangeSupports 3 Transmitter Channels for Multi-Zone OperationExcellent Ambient and Sunlight Rejection200-nA Full-Scale Signal Current88-dB Signal Phase Dynamic Range at 1 kHzSupports DC Ambient up to 200 µA, 60-dB Rejection for Ambient at 1 kHzDistance Measurement Independent of Object ReflectivityAdaptive HDR to Save Power and Increase the Dynamic RangeConfigurable Event Detection and Interrupt Output MechanismI2C Interface for Control and DataIntegrated Illumination Driver With Programmable Current Control up to 173 mAIntegrated Temperature Sensor for CalibrationSingle 3.3-V or 1.8-V and 3.3-V Supply OperationOperating Ambient Temperature: –40 to 85°C

Description

AI
The OPT3101 device is a high-speed, high-resolution AFE for continuous-wave, time-of-flight based proximity sensing and range finding. The device integrates the complete depth processing pipeline that includes the ADC, timing sequencer, and the digital processing engine. The device also has a built-in illumination driver that covers most of the target applications. Given the high ambient rejection ratio, the device can support very high ambient conditions, including full sunlight of 130 klx. The timing sequencer is highly configurable to provide for application-specific trade-offs of power versus performance. The device provides depth data that consists of phase, amplitude, and ambient measurements. The calibration subsystem supports phase-data calibration for inaccuracies resulting from temperature and crosstalk. The OPT3101 device is a high-speed, high-resolution AFE for continuous-wave, time-of-flight based proximity sensing and range finding. The device integrates the complete depth processing pipeline that includes the ADC, timing sequencer, and the digital processing engine. The device also has a built-in illumination driver that covers most of the target applications. Given the high ambient rejection ratio, the device can support very high ambient conditions, including full sunlight of 130 klx. The timing sequencer is highly configurable to provide for application-specific trade-offs of power versus performance. The device provides depth data that consists of phase, amplitude, and ambient measurements. The calibration subsystem supports phase-data calibration for inaccuracies resulting from temperature and crosstalk.