Zenode.ai Logo
Beta
K
M24M01-RDW6TP - 8-TSSOP

M24M01-RDW6TP

Active
STMicroelectronics

IC EEPROM 1MBIT I2C 1MHZ 8TSSOP

Deep-Dive with AI

Search across all available documentation for this part.

DocumentsDS5010+13
M24M01-RDW6TP - 8-TSSOP

M24M01-RDW6TP

Active
STMicroelectronics

IC EEPROM 1MBIT I2C 1MHZ 8TSSOP

Deep-Dive with AI

DocumentsDS5010+13

Technical Specifications

Parameters and characteristics for this part

SpecificationM24M01-RDW6TP
Access Time500 ns
Memory FormatEEPROM
Memory InterfaceI2C
Memory Organization128K x 8
Memory Size1 Mbit
Memory TypeNon-Volatile
Mounting TypeSurface Mount
Operating Temperature [Max]85 °C
Operating Temperature [Min]-40 °C
Package / Case8-TSSOP
Package / Case [custom]0.173 "
Package / Case [custom]4.4 mm
Supplier Device Package8-TSSOP
TechnologyEEPROM
Voltage - Supply [Max]5.5 V
Voltage - Supply [Min]1.8 V
Write Cycle Time - Word, Page5 ms

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 1.48
10$ 1.35
25$ 1.31
50$ 1.31
100$ 1.17
250$ 1.17
500$ 1.15
1000$ 1.10
Digi-Reel® 1$ 1.48
10$ 1.35
25$ 1.31
50$ 1.31
100$ 1.17
250$ 1.17
500$ 1.15
1000$ 1.10
Tape & Reel (TR) 4000$ 1.03
8000$ 1.02
NewarkEach (Supplied on Cut Tape) 1$ 1.64
10$ 1.56
25$ 1.52
50$ 1.49
100$ 1.47
250$ 1.43
500$ 1.41
1000$ 1.38

Description

General part information

M24M01-A125 Series

The M24M01E-F is a 1-Mbit I²C-compatible EEPROM (electrically erasable programmable memory) organized as 128 K × 8 bits. It can operate with a supply voltage from 1.6 V to 5.5 V with a clock frequency up to 1 MHz, over an ambient temperature range of -40 °C to +85 °C.

The device offers three 8-bit registers, namely: the device type identifier (DTI) register, the configurable device address (CDA), and the software write protection (SWP) register.

The device offers an additional 256-byte page, called the identification page. This page can be used to store sensitive application parameters, which can later be permanently locked in read-only mode.