Zenode.ai Logo
LM5060Q1MM/NOPB

LM5060Q1MM/NOPB

Active
Texas Instruments

HOT SWAP CONTROLLER 1-CH 65V N-CHANNEL POSITIVE VOLTAGE AUTOMOTIVE AEC-Q100 10-PIN VSSOP T/R

Find alt
LM5060Q1MM/NOPB

LM5060Q1MM/NOPB

Active
Texas Instruments

HOT SWAP CONTROLLER 1-CH 65V N-CHANNEL POSITIVE VOLTAGE AUTOMOTIVE AEC-Q100 10-PIN VSSOP T/R

Find alt

Description

General part information

LM5060 Series

The LM5060 high-side protection controller provides intelligent control of a high-side N-channel MOSFET during normal on/off transitions and fault conditions. In-rush current is controlled by the nearly constant rise time of the output voltage. A POWER GOOD output indicates when the output voltage reaches the input voltage and the MOSFET is fully on. Input UVLO (with hysteresis) is provided as well as programmable input OVP. An enable input provides remote on or off control. The programmable UVLO input can be used as second enable input for safety redundancy. A single capacitor programs the initial start-up VGSfault detection delay time, the transition VDSfault detection delay time, and the continuous over-current VDSfault detection delay time. When a detected fault condition persists longer than the allowed fault delay time, the MOSFET is latched off until either the enable input or the UVLO input is toggled low and then high.

The LM5060 high-side protection controller provides intelligent control of a high-side N-channel MOSFET during normal on/off transitions and fault conditions. In-rush current is controlled by the nearly constant rise time of the output voltage. A POWER GOOD output indicates when the output voltage reaches the input voltage and the MOSFET is fully on. Input UVLO (with hysteresis) is provided as well as programmable input OVP. An enable input provides remote on or off control. The programmable UVLO input can be used as second enable input for safety redundancy. A single capacitor programs the initial start-up VGSfault detection delay time, the transition VDSfault detection delay time, and the continuous over-current VDSfault detection delay time. When a detected fault condition persists longer than the allowed fault delay time, the MOSFET is latched off until either the enable input or the UVLO input is toggled low and then high.

Technical Specifications

Parameters and characteristics for this part

SpecificationLM5060Q1MM/NOPB
GradeAutomotive
Mounting TypeSurface Mount
Operating Temperature (Max)125 °C
Operating Temperature (Min)-40 °C
Package Length0.118 in
Package Name10-TFSOP, 10-MSOP, 10-VSSOP
Package Width3 mm
QualificationAEC-Q100