FN9280-10-06
ActiveTE Connectivity Raychem Cable Protection
PWR ENT MOD RCPT IEC320-C14 PNL
Deep-Dive with AI
Search across all available documentation for this part.
DocumentsDatasheet

FN9280-10-06
ActiveTE Connectivity Raychem Cable Protection
PWR ENT MOD RCPT IEC320-C14 PNL
Deep-Dive with AI
DocumentsDatasheet
Technical Specifications
Parameters and characteristics for this part
| Specification | FN9280-10-06 |
|---|---|
| Accomodates a Fuse | True |
| Approval Agency | UL, CQC, CSA, ENEC |
| Connector Style | IEC 320-C14 |
| Connector Type | Receptacle, Male Blades - Module |
| Current Rating - Filter | 10 A |
| Features | Front or Rear Side Mount |
| Filter Type | Filtered (EMI, RFI) - Commercial |
| Fuse Holder, Drawer | Fuse Holder, Twin Fused |
| Ingress Protection | IP40 |
| Material Flammability Rating | UL94 V-2 |
| Mounting Type | Panel Mount, Flange |
| Panel Cutout Dimensions [x] | 28.8 mm |
| Panel Cutout Dimensions [y] | 47.1 mm |
| Switch Features | Switch On-Off |
| Termination | 0.25 in |
| Termination | 6.3 mm |
| Termination | Quick Connect |
FN9280 Series
| Part | Fuse Holder, Drawer | Connector Type | Mounting Type | Material Flammability Rating | Ingress Protection | Features | Panel Thickness [Max] | Panel Thickness [Min] | Panel Thickness [Max] | Panel Thickness [Min] | Switch Features | Approval Agency | Termination | Termination | Termination | Connector Style | Accomodates a Fuse | Filter Type | Panel Cutout Dimensions [y] | Panel Cutout Dimensions [x] | Current Rating - Filter |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | 2.5 mm | 1 mm | 0.098 in | 0.039 in | Switch On-Off | CQC CSA ENEC UR | 0.25 in | 6.3 mm | Quick Connect | IEC 320-C14 | Filtered (EMI RFI) - Commercial Medical | 47.1 mm | 28.8 mm | 4 A | |
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | Switch On-Off | CQC CSA ENEC UL | 0.25 in | 6.3 mm | Quick Connect | IEC 320-C14 | Filtered (EMI RFI) - Commercial Medical | 47.1 mm | 28.8 mm | 6 A | |||||
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | Switch On-Off | CQC CSA ENEC UL | Spring-Cage | IEC 320-C14 | Filtered (EMI RFI) - Commercial | 47.1 mm | 28.8 mm | 6 A | |||||||
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | Switch On-Off | CQC CSA ENEC UL | Spring-Cage | IEC 320-C14 | Filtered (EMI RFI) - Commercial Medical | 47.1 mm | 28.8 mm | 6 A | |||||||
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | Switch On-Off | CQC CSA ENEC UL | Spring-Cage | IEC 320-C14 | Filtered (EMI RFI) - Commercial Medical | 47.1 mm | 28.8 mm | 4 A | |||||||
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | 2.5 mm | 1 mm | 0.098 in | 0.039 in | Switch On-Off | CQC CSA ENEC UR | 0.25 in | 6.3 mm | Quick Connect | IEC 320-C14 | Filtered (EMI RFI) - Commercial Medical | 47.1 mm | 28.8 mm | 4 A | |
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | 2.5 mm | 1 mm | 0.098 in | 0.039 in | Switch On-Off | CQC CSA ENEC UR | 0.25 in | 6.3 mm | Quick Connect | IEC 320-C14 | Filtered (EMI RFI) - Commercial Medical | 47.1 mm | 28.8 mm | 10 A | |
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | Switch On-Off | CQC CSA ENEC UL | 0.25 in | 6.3 mm | Quick Connect | IEC 320-C14 | Filtered (EMI RFI) - Commercial | 47.1 mm | 28.8 mm | 10 A | |||||
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | 2.5 mm | 1 mm | 0.098 in | 0.039 in | Switch On-Off | CQC CSA ENEC UR | 0.25 in | 6.3 mm | Quick Connect | IEC 320-C14 | Filtered (EMI RFI) - Commercial Medical | 47.1 mm | 28.8 mm | 6 A | |
TE Connectivity Raychem Cable Protection | Fuse Holder Twin Fused | Receptacle Male Blades - Module | Flange Panel Mount | UL94 V-2 | IP40 | Front or Rear Side Mount | Switch On-Off | CQC CSA ENEC UL | 0.25 in | 6.3 mm | Quick Connect | IEC 320-C14 | Filtered (EMI RFI) - Commercial | 47.1 mm | 28.8 mm | 6 A |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Bulk | 1 | $ 36.17 | |
| 10 | $ 31.68 | |||
| 40 | $ 29.33 | |||
| 80 | $ 28.35 | |||
| 280 | $ 26.79 | |||
Description
General part information
FN9280 Series
Power Entry Connector Receptacle, Male Blades - Module IEC 320-C14 Panel Mount, Flange
Documents
Technical documentation and resources