1-cell, 1-A, Li-ion battery charger with operation over JEITA and 100kΩ NTC
Part | Voltage - Supply (Max) [Max] | Mounting Type | Battery Pack Voltage | Charge Current - Max [Max] | Operating Temperature [Min] | Operating Temperature [Max] | Supplier Device Package | Number of Cells | Interface | Programmable Features | Package / Case | Fault Protection | Current - Charging | Battery Chemistry |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Texas Instruments BQ24093DGQT | 6.45 V | Surface Mount | 4.2 V | 1 A | 0 °C | 125 ¯C | 10-HVSSOP | 1 | USB | Current | 10-MSOP, 10-PowerTFSOP | Over Temperature, Over Voltage, Short Circuit | Constant - Programmable | Lithium Ion/Polymer |
Texas Instruments BQ24093DGQR | 6.45 V | Surface Mount | 4.2 V | 1 A | 0 °C | 125 ¯C | 10-HVSSOP | 1 | USB | Current | 10-MSOP, 10-PowerTFSOP | Over Temperature, Over Voltage, Short Circuit | Constant - Programmable | Lithium Ion/Polymer |
Key Features
• Charging1% charge voltage accuracy10% charge current accuracyPin selectable USB 100-mA and 500-mA maximum input current limitProgrammable termination and precharge thresholdProtection6.6-V overvoltage protectionInput voltage dynamic power management125°C thermal regulation; 150°C thermal shutdown protectionOUT short-circuit protection and ISET short detectionOperation over JEITA range via battery NTC – ½ fast-charge-current at cold, 4.06 V at hot, BQ092/3Fixed 10-hour safety timerSystemAutomatic Termination and Timer Disable Mode (TTDM) for absent battery pack with thermistorStatus indication – charging/doneAvailable in a small 10-pin MSOP packageCharging1% charge voltage accuracy10% charge current accuracyPin selectable USB 100-mA and 500-mA maximum input current limitProgrammable termination and precharge thresholdProtection6.6-V overvoltage protectionInput voltage dynamic power management125°C thermal regulation; 150°C thermal shutdown protectionOUT short-circuit protection and ISET short detectionOperation over JEITA range via battery NTC – ½ fast-charge-current at cold, 4.06 V at hot, BQ092/3Fixed 10-hour safety timerSystemAutomatic Termination and Timer Disable Mode (TTDM) for absent battery pack with thermistorStatus indication – charging/doneAvailable in a small 10-pin MSOP package
Description
AI
The BQ2409x series of devices are highly integrated Li-ion and Li-Pol linear chargers devices targeted at space-limited portable applications. The devices operate from either a USB port or AC adapter. The high input voltage range with input overvoltage protection supports low-cost unregulated adapters.
The BQ2409x has a single power output that charges the battery. A system load can be placed in parallel with the battery as long as the average system load does not keep the battery from charging fully during the 10-hour safety timer.
The battery is charged in three phases: conditioning, constant current and constant voltage. In all charge phases, an internal control loop monitors the IC junction temperature and reduces the charge current if an internal temperature threshold is exceeded.
The charger power stage and charge current sense functions are fully integrated. The charger function has high accuracy current and voltage regulation loops, charge status display, and charge termination. The pre-charge current and termination current threshold are programmed via an external resistor. The fast charge current value is also programmable via an external resistor.
The BQ2409x series of devices are highly integrated Li-ion and Li-Pol linear chargers devices targeted at space-limited portable applications. The devices operate from either a USB port or AC adapter. The high input voltage range with input overvoltage protection supports low-cost unregulated adapters.
The BQ2409x has a single power output that charges the battery. A system load can be placed in parallel with the battery as long as the average system load does not keep the battery from charging fully during the 10-hour safety timer.
The battery is charged in three phases: conditioning, constant current and constant voltage. In all charge phases, an internal control loop monitors the IC junction temperature and reduces the charge current if an internal temperature threshold is exceeded.
The charger power stage and charge current sense functions are fully integrated. The charger function has high accuracy current and voltage regulation loops, charge status display, and charge termination. The pre-charge current and termination current threshold are programmed via an external resistor. The fast charge current value is also programmable via an external resistor.