±100V basic isolation, 20Arms 80kHz Hall-effect current sensor with reference

Manufacturer: Texas Instruments

Catalog(1 parts)

PartUtilized IC / PartSensor TypeEmbeddedVoltage - SupplyVoltage - SupplySupplied Contents
Texas Instruments
TMCS1108EVM
TMCS1108 - Current Sensor Sensor Evaluation Board
TMCS1108
Current Sensor
3 V
5.5 V
Board(s)

Key Features

Total error: ±1% typical, ±3% maximum, –40°C to 125°CSensitivity error: ±0.9%Offset error: 40 mAOffset drift: 0.2 mA/°CLinearity error: 0.5%Multiple sensitivity options:TMCS1108A1B/U: 50 mV/ATMCS1108A2B/U: 100 mV/ATMCS1108A3B/U: 200 mV/ATMCS1108A4B/U: 400 mV/AZero drift internal referenceBidirectional and unidirectional current sensingOperating supply range: 3 V to 5.5 VSignal bandwidth: 80 kHzRobust 100-V galvanic isolationTotal error: ±1% typical, ±3% maximum, –40°C to 125°CSensitivity error: ±0.9%Offset error: 40 mAOffset drift: 0.2 mA/°CLinearity error: 0.5%Multiple sensitivity options:TMCS1108A1B/U: 50 mV/ATMCS1108A2B/U: 100 mV/ATMCS1108A3B/U: 200 mV/ATMCS1108A4B/U: 400 mV/AZero drift internal referenceBidirectional and unidirectional current sensingOperating supply range: 3 V to 5.5 VSignal bandwidth: 80 kHzRobust 100-V galvanic isolation

Description

AI
The TMCS1108 is a galvanically isolated Hall-effect current sensor capable of DC or AC current measurement with high accuracy, excellent linearity, and temperature stability. A low-drift, temperature-compensated signal chain provides <3% full-scale error across the device temperature range. The input current flows through an internal 1.8-mΩ conductor that generates a magnetic field measured by an integrated Hall-effect sensor. This structure eliminates external concentrators and simplifies design. Low conductor resistance minimizes power loss and thermal dissipation. Inherent galvanic insulation provides a 100-V functional isolation between the current path and circuitry. Integrated electrical shielding enables excellent common-mode rejection and transient immunity. The output voltage is proportional to the input current with multiple sensitivity options. Fixed sensitivity allows the TMCS1108 to operate from a single 3-V to 5.5-V power supply, eliminates ratiometry errors, and improves supply noise rejection. The current polarity is considered positive when flowing into the positive input pin. Both unidirectional and bidirectional sensing variants are available. The TMCS1108 draws a maximum supply current of 6 mA, and all sensitivity options are specified over the operating temperature range of –40°C to +125°C. The TMCS1108 is a galvanically isolated Hall-effect current sensor capable of DC or AC current measurement with high accuracy, excellent linearity, and temperature stability. A low-drift, temperature-compensated signal chain provides <3% full-scale error across the device temperature range. The input current flows through an internal 1.8-mΩ conductor that generates a magnetic field measured by an integrated Hall-effect sensor. This structure eliminates external concentrators and simplifies design. Low conductor resistance minimizes power loss and thermal dissipation. Inherent galvanic insulation provides a 100-V functional isolation between the current path and circuitry. Integrated electrical shielding enables excellent common-mode rejection and transient immunity. The output voltage is proportional to the input current with multiple sensitivity options. Fixed sensitivity allows the TMCS1108 to operate from a single 3-V to 5.5-V power supply, eliminates ratiometry errors, and improves supply noise rejection. The current polarity is considered positive when flowing into the positive input pin. Both unidirectional and bidirectional sensing variants are available. The TMCS1108 draws a maximum supply current of 6 mA, and all sensitivity options are specified over the operating temperature range of –40°C to +125°C.