TPS40192 Series

4.5-V to 18-V, 20-A, 600-kHz synchronous buck controller with power good

Manufacturer: Texas Instruments

Catalog(1 parts)

PartControl FeaturesSynchronous RectifierOutput PhasesTopologyClock SyncOutput ConfigurationVoltage - Supply (Vcc/Vdd)Voltage - Supply (Vcc/Vdd)FunctionMounting TypePackage / CaseOutput TypeOperating TemperatureOperating TemperatureFrequency - SwitchingSupplier Device PackageNumber of Outputs
Texas Instruments
TPS40192DRCR
Buck Regulator Positive Output Step-Down DC-DC Controller IC 10-VSON (3x3)
Enable, Power Good
1 ul
Buck
Positive
4.5 V
18 V
Step-Down
Surface Mount
10-VFDFN Exposed Pad
Transistor Driver
85 °C
-40 °C
600000 Hz
10-VSON (3x3)
1 ul

Key Features

Input Operating Voltage Range: 4.5 V to 18 VUp to 20-A Output CurrentsSupports Pre-Biased Outputs0.5%, 591-mV ReferenceSwitching FrequencyTPS40192: 600 kHzTPS40193: 300 kHzThree Selectable Thermally Compensated Short-Circuit Protection LevelsHiccup Restart from FaultsInternal 5-V RegulatorHigh-Side and Low-Side MOSFET ON-resistance (RDS(on)) Current Sensing10-Pin 3 mm × 3 mm SON PackageInternal 4-ms Soft-Start TimeThermal Shutdown Protection at 145°CInput Operating Voltage Range: 4.5 V to 18 VUp to 20-A Output CurrentsSupports Pre-Biased Outputs0.5%, 591-mV ReferenceSwitching FrequencyTPS40192: 600 kHzTPS40193: 300 kHzThree Selectable Thermally Compensated Short-Circuit Protection LevelsHiccup Restart from FaultsInternal 5-V RegulatorHigh-Side and Low-Side MOSFET ON-resistance (RDS(on)) Current Sensing10-Pin 3 mm × 3 mm SON PackageInternal 4-ms Soft-Start TimeThermal Shutdown Protection at 145°C

Description

AI
TPS40192 and TPS40193 are cost-optimized synchronous buck controllers that operate from 4.5 V to 18 V input. These controllers implement a voltage-mode control architecture with the switching frequency fixed at either 600 kHz (TPS40192) or 300 kHz (TPS40193). The higher switching frequency facilitates the use of smaller inductor and output capacitors, thereby providing a compact power-supply solution. An adaptive anti-cross conduction scheme is used to prevent shoot through current in the power FETs. Short circuit detection is done by sensing the voltage drop across the low-side MOSFET when it is on and comparing it with a user selected threshold of 100 mV, 200 mV or 280 mV. The threshold is set with a single external resistor connected from COMP to GND. This resistor is sensed at startup and the selected threshold is latched. Pulse-by-pulse limiting (to prevent current runaway) is provided by sensing the voltage across the high-side MOSFET when it is on and terminating the cycle when the voltage drop rises above a fixed threshold of 550 mV. When the controller senses an output short circuit, both MOSFETs are turned off and a timeout period is observed before attempting to restart. This behavior provides limited power dissipation in the event of a sustained fault. TPS40192 and TPS40193 are cost-optimized synchronous buck controllers that operate from 4.5 V to 18 V input. These controllers implement a voltage-mode control architecture with the switching frequency fixed at either 600 kHz (TPS40192) or 300 kHz (TPS40193). The higher switching frequency facilitates the use of smaller inductor and output capacitors, thereby providing a compact power-supply solution. An adaptive anti-cross conduction scheme is used to prevent shoot through current in the power FETs. Short circuit detection is done by sensing the voltage drop across the low-side MOSFET when it is on and comparing it with a user selected threshold of 100 mV, 200 mV or 280 mV. The threshold is set with a single external resistor connected from COMP to GND. This resistor is sensed at startup and the selected threshold is latched. Pulse-by-pulse limiting (to prevent current runaway) is provided by sensing the voltage across the high-side MOSFET when it is on and terminating the cycle when the voltage drop rises above a fixed threshold of 550 mV. When the controller senses an output short circuit, both MOSFETs are turned off and a timeout period is observed before attempting to restart. This behavior provides limited power dissipation in the event of a sustained fault.