Zenode.ai Logo

65HVD266 Series

'Turbo' CAN Transceiver for CAN FD (Flexible Data Rate) with I/O Level Shifting

Manufacturer: Texas Instruments

Catalog(2 parts)

PartMounting TypeTypeData RateDuplexProtocolSupplier Device PackageOperating TemperatureOperating TemperatureReceiver HysteresisVoltage - SupplyVoltage - SupplyPackage / CasePackage / Case
Texas Instruments
SN65HVD266D
1/1 Transceiver Half CANbus 8-SOIC
Surface Mount
Transceiver
2097152 bit/s
Half
CANbus
8-SOIC
125 °C
-40 °C
0.125 V
5.5 V
4.5 V
0.003899999894201755 m
8-SOIC
Texas Instruments
SN65HVD266DR
1/1 Transceiver Half CANbus 8-SOIC
Surface Mount
Transceiver
2097152 bit/s
Half
CANbus
8-SOIC
125 °C
-40 °C
0.125 V
5.5 V
4.5 V
0.003899999894201755 m
8-SOIC

Key Features

Meets the Requirements of ISO11898-2Turbo CAN:Specified for 2-Mbps CAN FD (CAN withFlexible Data Rate)Short and Symmetrical Propagation DelayTimes and Fast Loop Times for EnhancedTiming MarginHigher Data Rates in CAN NetworksI/O Voltage Range Supports 3.3-V and 5-V MCUsIdeal Passive Behavior When UnpoweredBus and Logic Terminals are High Impedance(no load)Power-Up/Down With Glitch Free OperationOn BusProtection FeaturesHBM ESD Protection Exceeds ±12 kVBus Fault Protection –27 V to 40 VUndervoltage Protection on Supply TerminalsDriver Dominant Time Out (TXD DTO)SN65HVD267: Receiver Dominant Time Out(RXD DTO)SN65HVD267: FAULT Output TerminalThermal Shutdown ProtectionCharacterized for –40°C to 125°C OperationMeets the Requirements of ISO11898-2Turbo CAN:Specified for 2-Mbps CAN FD (CAN withFlexible Data Rate)Short and Symmetrical Propagation DelayTimes and Fast Loop Times for EnhancedTiming MarginHigher Data Rates in CAN NetworksI/O Voltage Range Supports 3.3-V and 5-V MCUsIdeal Passive Behavior When UnpoweredBus and Logic Terminals are High Impedance(no load)Power-Up/Down With Glitch Free OperationOn BusProtection FeaturesHBM ESD Protection Exceeds ±12 kVBus Fault Protection –27 V to 40 VUndervoltage Protection on Supply TerminalsDriver Dominant Time Out (TXD DTO)SN65HVD267: Receiver Dominant Time Out(RXD DTO)SN65HVD267: FAULT Output TerminalThermal Shutdown ProtectionCharacterized for –40°C to 125°C Operation

Description

AI
This CAN transceiver meets the ISO1189-2 High Speed CAN (Controller Area Network) physical layer standard. It is designed for data rates in excess of 2 Mpbs (megabits per second) for CAN FD (CAN with flexible data rate), greater than 1 Mbps for CAN in short networks, and enhanced timing margin and higher data rates in long and highly-loaded networks. The device provides many protection features to enhance device and CAN-network robustness. The SN65HVD267 adds additional features, allowing easy design of redundant and multi-topology networks with fault indication for higher levels of safety in the CAN system. This CAN transceiver meets the ISO1189-2 High Speed CAN (Controller Area Network) physical layer standard. It is designed for data rates in excess of 2 Mpbs (megabits per second) for CAN FD (CAN with flexible data rate), greater than 1 Mbps for CAN in short networks, and enhanced timing margin and higher data rates in long and highly-loaded networks. The device provides many protection features to enhance device and CAN-network robustness. The SN65HVD267 adds additional features, allowing easy design of redundant and multi-topology networks with fault indication for higher levels of safety in the CAN system.