LINE FILTER 80A CHASSIS MOUNT
| Part | Voltage - Rated AC (Phase to Phase) | Filter Type | Voltage - Rated AC (Phase to Ground/Neutral) | Mounting Type | Operating Temperature [custom] | Current | Approval Agency | Frequency - Operating [Max] | Frequency - Operating [Min] | Applications | Configuration | Termination Style | Operating Temperature [Min] | Operating Temperature [Max] |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TE Connectivity Raychem Cable Protection | 520 V | Three Phase (Delta) | 300 V | Chassis Mount | -25 °C 100 °C | 80 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | ||
TE Connectivity Raychem Cable Protection | 520 V | Three Phase (Delta) | 300 V | Chassis Mount | -25 °C 100 °C | 8 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | ||
TE Connectivity Raychem Cable Protection | 440 V | Three Phase (Delta) | 250 V | Chassis Mount | 36 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | -25 °C | 85 °C | |
TE Connectivity Raychem Cable Protection | 440 V | Three Phase (Delta) | 250 V | Chassis Mount | 64 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | -25 °C | 85 °C | |
TE Connectivity Raychem Cable Protection | 520 V | Three Phase (Delta) | 300 V | Chassis Mount | -25 °C 100 °C | 36 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | ||
TE Connectivity Raychem Cable Protection | 520 V | Three Phase (Delta) | 300 V | Chassis Mount | -25 °C 100 °C | 64 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | ||
TE Connectivity Raychem Cable Protection | 520 V | Three Phase (Delta) | 300 V | Chassis Mount | -25 °C 100 °C | 110 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | ||
TE Connectivity Raychem Cable Protection | 440 V | Three Phase (Delta) | 250 V | Chassis Mount | 16 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | -25 °C | 85 °C | |
TE Connectivity Raychem Cable Protection | 440 V | Three Phase (Delta) | 250 V | Chassis Mount | 16 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | -25 °C | 85 °C | |
TE Connectivity Raychem Cable Protection | 440 V | Three Phase (Delta) | 250 V | Chassis Mount | 50 A | CSA ENEC UR | 60 Hz | DC | Inverters Power Drive Systems | Single Stage | Terminal Block | -25 °C | 85 °C |