ADS1118-Q1 Series
Automotive 16-bit, 860-SPS, 4-ch, delta-sigma ADC with PGA, oscillator, VREF, temp sensor and SPI
Manufacturer: Texas Instruments
Link to Manufacturer Page: https://www.ti.com/
Catalog
Automotive 16-bit, 860-SPS, 4-ch, delta-sigma ADC with PGA, oscillator, VREF, temp sensor and SPI
Part | Voltage - Supply, Digital [Min] | Voltage - Supply, Digital [Max] | Voltage - Supply, Analog [Min] | Voltage - Supply, Analog [Max] | Reference Type | Input Type | Configuration | Operating Temperature [Max] | Operating Temperature [Min] | Supplier Device Package | Package / Case | Number of Bits | Data Interface | Grade | Sampling Rate (Per Second) | Qualification | Number of Inputs | Number of A/D Converters | Architecture | Features | Mounting Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Texas Instruments ADS1118QDGSRQ1 | 2 V | 5.5 V | 2 V | 5.5 V | Internal | Differential, Single Ended | MUX-PGA-ADC | 125 °C | -40 °C | 10-VSSOP | 10-MSOP, 10-TFSOP | 16 bits | SPI | Automotive | 860 | AEC-Q100 | 2, 4 | 1 | Sigma-Delta | PGA, Temperature Sensor | Surface Mount |
Key Features
• AEC-Q100 qualified for automotive applications:Temperature grade 1: –40°C to +125°C, TAFunctional Safety-CapableDocumentation available to aid functional safety system designWide supply range: 2 V to 5.5 VLow current consumption:Continuous mode: only 150 µASingle-shot mode: automatic power-downProgrammable data rate: 8 SPS to 860 SPSSingle-cycle settlingInternal low-drift voltage referenceInternal temperature sensor:2°C (maximum) errorInternal oscillatorInternal PGAFour single-ended or two differential inputsAEC-Q100 qualified for automotive applications:Temperature grade 1: –40°C to +125°C, TAFunctional Safety-CapableDocumentation available to aid functional safety system designWide supply range: 2 V to 5.5 VLow current consumption:Continuous mode: only 150 µASingle-shot mode: automatic power-downProgrammable data rate: 8 SPS to 860 SPSSingle-cycle settlingInternal low-drift voltage referenceInternal temperature sensor:2°C (maximum) errorInternal oscillatorInternal PGAFour single-ended or two differential inputs
Description
AI
The ADS1118-Q1 is a precision, low power, 16-bit analog-to-digital converter (ADC) that provides all features necessary to measure the most common sensor signals. The ADS1118-Q1 integrates a programmable gain amplifier (PGA), voltage reference, oscillator, and high-accuracy temperature sensor. These features, along with a wide power-supply range from 2 V to 5.5 V, make theADS1118-Q1 ideally suited for power- and space-constrained, sensor-measurement applications.
The ADS1118-Q1 performs conversions at data rates up to 860 samples per second (SPS). The PGA offers input ranges from ±256 mV to ±6.144 V, allowing both large and small signals to be measured with high resolution. An input multiplexer (mux) allows measurement of two differential or four single-ended inputs. The high-accuracy temperature sensor is used for system-level temperature monitoring, or cold-junction compensation for thermocouples.
The ADS1118-Q1 operates either in continuous-conversion mode, or in a single-shot mode that automatically powers down after a conversion. Single-shot mode significantly reduces current consumption during idle periods. Data are transferred through a serial peripheral interface (SPI™). The ADS1118-Q1 is specified from –40°C to +125°C.
The ADS1118-Q1 is a precision, low power, 16-bit analog-to-digital converter (ADC) that provides all features necessary to measure the most common sensor signals. The ADS1118-Q1 integrates a programmable gain amplifier (PGA), voltage reference, oscillator, and high-accuracy temperature sensor. These features, along with a wide power-supply range from 2 V to 5.5 V, make theADS1118-Q1 ideally suited for power- and space-constrained, sensor-measurement applications.
The ADS1118-Q1 performs conversions at data rates up to 860 samples per second (SPS). The PGA offers input ranges from ±256 mV to ±6.144 V, allowing both large and small signals to be measured with high resolution. An input multiplexer (mux) allows measurement of two differential or four single-ended inputs. The high-accuracy temperature sensor is used for system-level temperature monitoring, or cold-junction compensation for thermocouples.
The ADS1118-Q1 operates either in continuous-conversion mode, or in a single-shot mode that automatically powers down after a conversion. Single-shot mode significantly reduces current consumption during idle periods. Data are transferred through a serial peripheral interface (SPI™). The ADS1118-Q1 is specified from –40°C to +125°C.