Zenode.ai Logo

UCC3884 Series

Frequency Foldback current mode PWM controller, 0°C to 70°C

Manufacturer: Texas Instruments

Catalog(3 parts)

PartPackage / CasePackage / CaseDuty Cycle (Max)Output ConfigurationOutput TypeOutput PhasesClock SyncSynchronous RectifierMounting TypeNumber of OutputsOperating TemperatureOperating TemperatureControl FeaturesSupplier Device PackageFunctionVoltage - Supply (Vcc/Vdd)Voltage - Supply (Vcc/Vdd)Topology
Texas Instruments
UCC3884D
Buck, Boost, Flyback, Forward Converter Regulator Positive Output Step-Up, Step-Down, Step-Up/Step-Down DC-DC Controller IC 16-SOIC
16-SOIC
0.003911599982529879 m, 3.900000095367432 ul
0.7799999713897705 ul
Positive
Transistor Driver
1 ul
Surface Mount
1 ul
70 °C
0 °C
Enable
16-SOIC
Step-Down, Step-Up, Step-Up/Step-Down
15 V
8.300000190734863 V
Boost, Buck, Flyback, Forward Converter
Texas Instruments
UCC3884N
Buck, Boost, Flyback, Forward Converter Regulator Positive Output Step-Up, Step-Down, Step-Up/Step-Down DC-DC Controller IC 16-PDIP
16-DIP
0.007619999814778566 m, 0.007619999814778566 m
0.7799999713897705 ul
Positive
Transistor Driver
1 ul
Through Hole
1 ul
70 °C
0 °C
Enable
16-PDIP
Step-Down, Step-Up, Step-Up/Step-Down
15 V
8.300000190734863 V
Boost, Buck, Flyback, Forward Converter
Texas Instruments
UCC3884NG4
Buck, Boost, Flyback, Forward Converter Regulator Positive Output Step-Up, Step-Down, Step-Up/Step-Down DC-DC Controller IC 16-PDIP
16-DIP
0.007619999814778566 m, 0.007619999814778566 m
0.7799999713897705 ul
Positive
Transistor Driver
1 ul
Through Hole
1 ul
70 °C
0 °C
Enable
16-PDIP
Step-Down, Step-Up, Step-Up/Step-Down
15 V
8.300000190734863 V
Boost, Buck, Flyback, Forward Converter

Key Features

Frequency Foldback Reduces Operating Frequency Under Fault ConditionsAccurate Programmable Volt-Second ClampProgrammable Maximum Duty Cycle ClampOscillator SynchronizationOvercurrent ProtectionShutdown With Full Soft StartWide Gain Bandwidth Amplifier (GBW > 2.5 MHz)Current Mode OperationPrecision 5-V ReferenceFrequency Foldback Reduces Operating Frequency Under Fault ConditionsAccurate Programmable Volt-Second ClampProgrammable Maximum Duty Cycle ClampOscillator SynchronizationOvercurrent ProtectionShutdown With Full Soft StartWide Gain Bandwidth Amplifier (GBW > 2.5 MHz)Current Mode OperationPrecision 5-V Reference

Description

AI
The UCC3884 is a high performance current mode PWM controller intended for single ended switch mode power supplies. The chip implements a frequency foldback scheme that decreases the oscillator frequency as the output voltage falls below a programmed value. This technique decreases the average output current sourced into a low impedance load which can occur during an output short circuit or overload condition. Excessive short circuit current is more prevalent in high frequency converters where the propagation delay and switch turn-off time forces a minimum attainable duty cycle. An accurate volt-second clamp limits the duty cycle during line or load transient conditions which could otherwise saturate the transformer. The volt-second clamp may also be used with an external overvoltage protection circuit to handle fault conditions such as current sense disconnect or current transformer saturation. The frequency foldback, volt-second clamp, cycle-by-cycle current limit, and overcurrent shutdown provide a rich set of protection features for use in peak current-mode pulse width modulators. The UCC3884 is a high performance current mode PWM controller intended for single ended switch mode power supplies. The chip implements a frequency foldback scheme that decreases the oscillator frequency as the output voltage falls below a programmed value. This technique decreases the average output current sourced into a low impedance load which can occur during an output short circuit or overload condition. Excessive short circuit current is more prevalent in high frequency converters where the propagation delay and switch turn-off time forces a minimum attainable duty cycle. An accurate volt-second clamp limits the duty cycle during line or load transient conditions which could otherwise saturate the transformer. The volt-second clamp may also be used with an external overvoltage protection circuit to handle fault conditions such as current sense disconnect or current transformer saturation. The frequency foldback, volt-second clamp, cycle-by-cycle current limit, and overcurrent shutdown provide a rich set of protection features for use in peak current-mode pulse width modulators.