Zenode.ai Logo

74V215 Series

512 x 18 Synchronous FIFO Memory

Manufacturer: Texas Instruments

Catalog(1 parts)

PartBus DirectionalRetransmit CapabilityPackage / CaseFunctionSupplier Device PackageCurrent - Supply (Max)Programmable Flags SupportFWFT SupportMounting TypeExpansion TypeOperating TemperatureOperating TemperatureData RateAccess TimeVoltage - SupplyVoltage - Supply
Texas Instruments
SN74V215-7PAG
Synchronous FIFO 9K (512 x 18) Uni-Directional 133MHz 5ns 64-TQFP (10x10)
Uni-Directional
64-TQFP
Synchronous
64-TQFP (10x10)
0.03500000014901161 A
Surface Mount
Depth, Width
70 °C
0 °C
133000000 Hz
4.999999969612645e-9 s
3 V
3.5999999046325684 V

Key Features

512 × 18-Bit Organization Array (SN74V215)1024 × 18-Bit Organization Array (SN74V225)2048 × 18-Bit Organization Array (SN74V235)4096 × 18-Bit Organization Array (SN74V245)7.5-ns Read/Write Cycle Time3.3-V VCC, 5-V Input TolerantFirst-Word or Standard Fall-Through TimingSingle or Double Register-Buffered Empty and Full FlagsEasily Expandable in Depth and WidthAsynchronous or Coincident Read and Write ClocksAsynchronous or Synchronous Programmable Almost-Empty and Almost-Full Flags With Default SettingsHalf-Full Flag CapabilityOutput Enable Puts Output Data Bus in High-Impedance StateHigh-Performance Submicron CMOS TechnologyPackaged in 64-Pin Thin Quad Flat PackageDSP and Microprocessor Interface Control LogicProvide a DSP Glueless Interface to Texas Instruments TMS320™ DSPsDSP-SYNC and TMS320 are trademarks of Texas Instruments.512 × 18-Bit Organization Array (SN74V215)1024 × 18-Bit Organization Array (SN74V225)2048 × 18-Bit Organization Array (SN74V235)4096 × 18-Bit Organization Array (SN74V245)7.5-ns Read/Write Cycle Time3.3-V VCC, 5-V Input TolerantFirst-Word or Standard Fall-Through TimingSingle or Double Register-Buffered Empty and Full FlagsEasily Expandable in Depth and WidthAsynchronous or Coincident Read and Write ClocksAsynchronous or Synchronous Programmable Almost-Empty and Almost-Full Flags With Default SettingsHalf-Full Flag CapabilityOutput Enable Puts Output Data Bus in High-Impedance StateHigh-Performance Submicron CMOS TechnologyPackaged in 64-Pin Thin Quad Flat PackageDSP and Microprocessor Interface Control LogicProvide a DSP Glueless Interface to Texas Instruments TMS320™ DSPsDSP-SYNC and TMS320 are trademarks of Texas Instruments.

Description

AI
The SN74V215, SN74V225, SN74V235, and SN74V245 are very high-speed, low-power CMOS clocked first-in first-out (FIFO) memories. They support clock frequencies up to 133 MHz and have read-access times as fast as 5 ns. These DSP-Sync™ FIFO memories feature read and write controls for use in applications such as DSP-to-processor communication, DSP-to-analog front end (AFE) buffering, network, video, and data communications. These are synchronous FIFOs, which means each port employs a synchronous interface. All data transfers through a port are gated to the low-to-high transition of a continuous (free-running) port clock by enable signals. The continuous clocks for each port are independent of one another and can be asynchronous or coincident. The enables for each port are arranged to provide a simple interface between DSPs, microprocessors, and/or buses controlled by a synchronous interface. An output-enable (OE)\ input controls the 3-state output. The synchronous FIFOs have two fixed flags, empty flag/output ready (EF\/OR\) and full flag/input ready (FF\/IR\), and two programmable flags, almost-empty (PAE)\ and almost-full (PAF)\. The offset loading of the programmable flags is controlled by a simple state machine, and is initiated by asserting the load pin (LD)\. A half-full flag (HF)\ is available when the FIFO is used in a single-device configuration. Two timing modes of operation are possible with these devices: first-word fall-through (FWFT) mode and standard mode. In FWFT mode, the first word written to an empty FIFO is clocked directly to the data output lines after three transitions of the RCLK signal. A read enable (REN)\ does not have to be asserted for accessing the first word. In standard mode, the first word written to an empty FIFO does not appear on the data output lines unless a specific read operation is performed. A read operation, which consists of activating REN\ and enabling a rising RCLK edge, shifts the word from internal memory to the data output lines. These devices are depth expandable, using a daisy-chain technique or FWFT mode. The XI\ and XO\ pins are used to expand the FIFOs. In depth-expansion configuration, first load (FL)\ is grounded on the first device and set to high for all other devices in the daisy chain. The SN74V215, SN74V225, SN74V235, and SN74V245 are characterized for operation from 0°C to 70°C. The SN74V215, SN74V225, SN74V235, and SN74V245 are very high-speed, low-power CMOS clocked first-in first-out (FIFO) memories. They support clock frequencies up to 133 MHz and have read-access times as fast as 5 ns. These DSP-Sync™ FIFO memories feature read and write controls for use in applications such as DSP-to-processor communication, DSP-to-analog front end (AFE) buffering, network, video, and data communications. These are synchronous FIFOs, which means each port employs a synchronous interface. All data transfers through a port are gated to the low-to-high transition of a continuous (free-running) port clock by enable signals. The continuous clocks for each port are independent of one another and can be asynchronous or coincident. The enables for each port are arranged to provide a simple interface between DSPs, microprocessors, and/or buses controlled by a synchronous interface. An output-enable (OE)\ input controls the 3-state output. The synchronous FIFOs have two fixed flags, empty flag/output ready (EF\/OR\) and full flag/input ready (FF\/IR\), and two programmable flags, almost-empty (PAE)\ and almost-full (PAF)\. The offset loading of the programmable flags is controlled by a simple state machine, and is initiated by asserting the load pin (LD)\. A half-full flag (HF)\ is available when the FIFO is used in a single-device configuration. Two timing modes of operation are possible with these devices: first-word fall-through (FWFT) mode and standard mode. In FWFT mode, the first word written to an empty FIFO is clocked directly to the data output lines after three transitions of the RCLK signal. A read enable (REN)\ does not have to be asserted for accessing the first word. In standard mode, the first word written to an empty FIFO does not appear on the data output lines unless a specific read operation is performed. A read operation, which consists of activating REN\ and enabling a rising RCLK edge, shifts the word from internal memory to the data output lines. These devices are depth expandable, using a daisy-chain technique or FWFT mode. The XI\ and XO\ pins are used to expand the FIFOs. In depth-expansion configuration, first load (FL)\ is grounded on the first device and set to high for all other devices in the daisy chain. The SN74V215, SN74V225, SN74V235, and SN74V245 are characterized for operation from 0°C to 70°C.