Zenode.ai Logo

74LS299 Series

Universal shift / storage registers

Manufacturer: Texas Instruments

Catalog(2 parts)

PartPackage / CasePackage / CaseNumber of ElementsFunctionOperating TemperatureOperating TemperatureSupplier Device PackageMounting TypeLogic TypeOutput TypeNumber of Bits per ElementVoltage - SupplyVoltage - Supply
Texas Instruments
SN74LS299DWR
Shift Shift Register 1 Element 8 Bit 20-SOIC
0.007493000011891127 m, 0.007499999832361937 m
20-SOIC
1 ul
Universal
70 °C
0 °C
20-SOIC
Surface Mount
Shift Register
Tri-State
8 ul
4.75 V
5.25 V
Texas Instruments
SN74LS299DW
Shift Shift Register 1 Element 8 Bit 20-SOIC
0.007493000011891127 m, 0.007499999832361937 m
20-SOIC
1 ul
Universal
70 °C
0 °C
20-SOIC
Surface Mount
Shift Register
Tri-State
8 ul
4.75 V
5.25 V

Key Features

Multiplexed Inputs/Outputs Provide Improved Bit DensityFour Modes of Operations:Hold (Store)Shift LeftShift RightLoad DataOperates with Outputs Enabled or at High Z3-State Outputs Drive Bus Lines DirectlyCan Be Cascaded for N-Bit Word LengthsSN54LS323 and SN74LS323 Are Similar But Have Synchronous ClearApplications:Stacked or Push-Down Registers Buffer Storage, and Accumulator RegistersMultiplexed Inputs/Outputs Provide Improved Bit DensityFour Modes of Operations:Hold (Store)Shift LeftShift RightLoad DataOperates with Outputs Enabled or at High Z3-State Outputs Drive Bus Lines DirectlyCan Be Cascaded for N-Bit Word LengthsSN54LS323 and SN74LS323 Are Similar But Have Synchronous ClearApplications:Stacked or Push-Down Registers Buffer Storage, and Accumulator Registers

Description

AI
These Schottky TTL eight-bit universal registers feature multiplexed inputs/outputs to achieve full eight-bit data handling in a single 20-pin package. Two function-select inputs and two output-control inputs can be used to choose the modes of operation listed in the function table. Synchronous parallel loading is accomplished by taking both function-select lines, S0 and S1, high. This places the three-state outputs in a high-impedance state, which permits data that is applied on the input/output lines to be clocked into the register. Reading out of the register can be accomplished while the outputs are enabled in any mode. A direct overriding input is provided to clear the register whether the outputs are enabled or off. These Schottky TTL eight-bit universal registers feature multiplexed inputs/outputs to achieve full eight-bit data handling in a single 20-pin package. Two function-select inputs and two output-control inputs can be used to choose the modes of operation listed in the function table. Synchronous parallel loading is accomplished by taking both function-select lines, S0 and S1, high. This places the three-state outputs in a high-impedance state, which permits data that is applied on the input/output lines to be clocked into the register. Reading out of the register can be accomplished while the outputs are enabled in any mode. A direct overriding input is provided to clear the register whether the outputs are enabled or off.