Zenode.ai Logo
Beta
K
LT8392JUFD#PBF - 28-QFN_05-08-1712 rev B

LT8392JUFD#PBF

Active
Analog Devices

60V SYNCHRONOUS 4-SWITCH BUCK-BOOST CONTROLLER WITH SPREAD SPECTRUM

Deep-Dive with AI

Search across all available documentation for this part.

LT8392JUFD#PBF - 28-QFN_05-08-1712 rev B

LT8392JUFD#PBF

Active
Analog Devices

60V SYNCHRONOUS 4-SWITCH BUCK-BOOST CONTROLLER WITH SPREAD SPECTRUM

Deep-Dive with AI

Technical Specifications

Parameters and characteristics for this part

SpecificationLT8392JUFD#PBF
Clock SyncTrue
Control FeaturesSoft Start, Power Good, Enable, Frequency Control
Frequency - Switching400 kHz
FunctionStep-Up/Step-Down
Mounting TypeSurface Mount
Number of Outputs1
Operating Temperature [Max]150 °C
Operating Temperature [Min]-40 °C
Output ConfigurationPositive
Output Phases2
Output TypeTransistor Driver
Package / Case28-WFQFN Exposed Pad
Supplier Device Package28-QFN (4x5)
Synchronous RectifierTrue
TopologyBuck-Boost
Voltage - Supply (Vcc/Vdd) [Max]60 V
Voltage - Supply (Vcc/Vdd) [Min]3 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyTube 1$ 14.64
10$ 10.18
73$ 7.97
146$ 7.61

Description

General part information

LT8392 Series

The LT8392 is a synchronous 4-switch buck-boost DC/ DC controller that regulates output voltage, input or output current from input voltage above, below, or equal to the output voltage. The proprietary peak-buck peak-boost current mode control scheme allows adjustable and synchronizable 150kHz to 650kHz fixed frequency operation, or internal ±15% triangle spread spectrum operation for low EMI. With 3V to 60V input voltage range, 1V to 60V output voltage capability, and seamless low noise transitions between operation regions, the LT8392 is ideal for voltage regulator, battery and super-capacitor charger applications in automotive, industrial, telecom, and even battery-powered systems.The LT8392 provides input or output current monitor and power good flag. Fault protection function detects output short-circuit condition, during which the LT8392 retries, latches off, or keeps running.