Zenode.ai Logo
MAX6698UE38+

MAX6698UE38+

Active
Analog Devices Inc./Maxim Integrated

7-CHANNEL PRECISION REMOTE-DIODE, THERMISTOR, AND LOCAL TEMPERATURE MONITOR

Find alt
MAX6698UE38+

MAX6698UE38+

Active
Analog Devices Inc./Maxim Integrated

7-CHANNEL PRECISION REMOTE-DIODE, THERMISTOR, AND LOCAL TEMPERATURE MONITOR

Find alt

Description

General part information

MAX6698 Series

The MAX6698 precision multichannel temperature sensor monitors its own temperature, the temperatures of three external diode-connected transistors, and the temperatures of three thermistors. All temperature channels have programmable alert thresholds. Channels 1, 4, 5, and 6 also have programmable overtemperature thresholds. When the measured temperature of a channel exceeds the respective threshold, a status bit is set in one of the status registers. Two open-drain outputs, active-low OVERT and active-low ALERT, assert corresponding to these bits in the status register.The 2-wire serial interface supports the standard system management bus (SMBus™) protocols: write byte, read byte, send byte, and receive byte for reading the temperature data and programming the alarm thresholds.The MAX6698 is specified for an operating temperature range of -40°C to +125°C and is available in 16-pin QSOP and 16-pin TSSOP packages.ApplicationsDesktop ComputersNotebook ComputersServersWorkstations

Technical Specifications

Parameters and characteristics for this part

SpecificationMAX6698UE38+
Accuracy - Highest2.5 °C
Accuracy - Lowest3.5 °C
FeaturesStandby Mode, Output Switch, One-Shot, Programmable Limit
Mounting TypeSurface Mount
Operating Temperature (Max)125 °C
Operating Temperature (Min)-40 °C
Output TypeSMBus
Package Length0.173 in
Package Name16-TSSOP
Package Width4.4 mm
Resolution (Local)11 b
Resolution (Remote)8 b
Sensing Temperature - Local (Max)125 °C
Sensing Temperature - Local (Min)-40 °C
Sensing Temperature - Remote (Max)125 °C
Sensing Temperature - Remote (Min)-40 °C
Sensor TypeDigital, Local/Remote
Test Condition (Alternate) Maximum125 ¯C
Test Condition (Alternate) Minimum0 °C
Test Condition (Primary) Maximum100 ¯C
Test Condition (Primary) Minimum60 °C
Voltage - Supply (Maximum)5.5 V
Voltage - Supply (Minimum)3 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

Sign in to see pricing

Create a free account to access distributor pricing data.

CAD

3D models and CAD resources for this part