Technical Specifications

Parameters and characteristics for this part

SpecificationSTEF033AJR
FunctionElectronic Fuse
Mounting TypeSurface Mount
Operating Temperature [Max]125 ¯C
Operating Temperature [Min]-40 °C
Package / Case9-UFBGA, FCBGA
Supplier Device Package9-FlipChip
Supplier Device Package [x]1.19
Supplier Device Package [y]1.19

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyCut Tape (CT) 1$ 1.26
10$ 1.13
25$ 1.07
100$ 0.88
250$ 0.82
500$ 0.73
1000$ 0.57
2500$ 0.54
Digi-Reel® 1$ 1.26
10$ 1.13
25$ 1.07
100$ 0.88
250$ 0.82
500$ 0.73
1000$ 0.57
2500$ 0.54
Tape & Reel (TR) 5000$ 0.53
10000$ 0.50
15000$ 0.49

Description

General part information

STEF033 Series

The STEF033 is an integrated electronic fuse optimized for monitoring output current and the input voltage. Connected in series to the 3.3 V rail, it is able to protect the electronic circuitry on its output from overcurrent and overvoltage. The STEF033 has controlled delay and turn-on time. When an overload condition occurs, the device limits the output current to a predefined safe value. If the anomalous overload condition persists, it goes into an open state, disconnecting the load from the power supply. If a continuous short-circuit is present on the board, when the power is re-applied the E-fuse initially limits the output current to a safe value and then goes again into the open state. The voltage clamping circuit prevents the output voltage from exceeding a fixed value, if the input voltage goes beyond this threshold. The device is equipped with a thermal protection circuit. Intervention of thermal protection is signaled to the board-monitoring circuits through an appropriate signal on the Fault pin. Unlike mechanical fuses, which must be physically replaced after a single event, the E-fuse does not degrade in its performances following short-circuit/thermal protection intervention and is reset either by re-cycling the supply voltage or using the appropriate Enable pin. The STEF033 is also available in an auto-retry version; in case of thermal fault it automatically attempts to re-apply power to the load when the die temperature returns to a safe value.

Documents

Technical documentation and resources