MAX30009 Series

The MAX30009 is a complete Bioimpedance (BioZ) Analog Front-End (AFE) solution for wearable applications. It offers high performance for fitness, wellness, and clinical applications, and ultra-low power for long battery life. The BioZ receive channel has Electrostatic Discharge (ESD) protection, Electromagnetic Interference (EMI) filtering, internal lead-biasing, DC leads-off detection, DRVN lead-off detection, and ultra-low power lead-on detection during standby mode. The BioZ receive channel also has high input impedance, low noise, high Common-Mode Rejection Ratio (CMRR), programmable gain, various low-pass and high-pass filter options, and two high resolution analog-to-digital converters for simultaneous I and Q acquisition.The BioZ transmit channel has a sine-wave current generator to drive AC currents into the body with a wide frequency range of 16Hz to 500kHz and a wide magnitude range of of 16nARMSto 1.28mARMS. The transmit channel can also operate in the sine-wave voltage and H-bridge modes. The flexible input/output MUX allows for both bipolar and tetrapolar measurements with multiple sets of electrodes.For measurements requiring high absolute impedance accuracy such as Bioimpedance Analysis/Spectroscopy (BIA/BIS) and Automated External Defibrillator (AED) body impedance, the MAX30009 offers several calibration options. An external precision resistor can be connected to the four-wire calibration port for the highest accuracy. Internal trimmed resistors also provide high accuracy.The PLL-based timing subsystem allows for a wide range of fine-tuned stimulus and sampling frequencies, and can be synchronized with other Analog Devices biosensors for simultaneous data collection.The MAX30009 is available in a 2.03mm x 2.03mm, 25-bump Wafer-Level Package (WLP), operating over the -40°C to +85°C temperature range.ApplicationsWearable Fitness, Wellness, and Medical DevicesMultifrequency Body Composition AnalyzersNon-Invasive Hemodynamic MonitorsAutomatic External DefibrillatorsOptimized Performance to Accurately Detect:Respiration RateGalvanic Skin Response/Electrodermal ActivityBioimpedance SpectroscopyBody Composition and Fluid AnalysisImpedance Cardiography and Plethysmography

Technical Specifications

Parameters and characteristics for this part

SpecificationMAX30009ENA+
Mounting TypeSurface Mount
Number of Bits20 bits
Number of Channels2
Package / Case25-XFBGA, WLBGA
Package Length2.03 mm
Package Name25-WLP
Package Width2.03 mm
Voltage - Supply, Analog (Max)2 V
Voltage - Supply, Analog (Min)1.7 V
Voltage - Supply, Digital (Max)2 V
Voltage - Supply, Digital (Min)1.7 V