Technical Specifications
Parameters and characteristics for this part
| Specification | SMC30J130CA |
|---|---|
| Applications | General Purpose |
| Bidirectional Channels [custom] | 1 |
| Current - Peak Pulse (10/1000µs) | 14 A |
| Mounting Type | Surface Mount |
| Operating Temperature [Max] | 175 ░C |
| Operating Temperature [Min] | -55 °C |
| Package / Case | SMC, DO-214AB |
| Power - Peak Pulse | 3000 W |
| Power - Peak Pulse | 3 kW |
| Power Line Protection | False |
| Supplier Device Package | SMC |
| Type | Zener |
| Voltage - Breakdown (Min) [Min] | 144 V |
| Voltage - Clamping (Max) @ Ipp [Max] | 209 V |
| Voltage - Reverse Standoff (Typ) | 130 V |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Bulk | 2500 | $ 0.58 | |
Description
General part information
SMC30J8.5CA Series
The SMC30J TVS series are designed to protect sensitive equipment against electrostatic discharges according to IEC 61000-4-2, MIL STD 883 Method 3015, and electrical overstress such as IEC 61000-4-4 and 5. They are used for surges below 3000 W 10/1000 μs.
This planar technology makes it compatible with high-end equipment and SMPS where low leakage current and high junction temperature are required to provide reliability and stability over time.
Documents
Technical documentation and resources
Flyers
AN5958
Application Notes (5 of 11)AN319
Application Notes (5 of 11)AN5686
Application Notes (5 of 11)AN574
Application Notes (5 of 11)AN4160
Application Notes (5 of 11)TN1310
Technical Notes & ArticlesFlyers