Technical Specifications
Parameters and characteristics commom to parts in this series
Specification | CT1S8 | CT1S8 Series |
---|---|---|
- | - | |
Delay Time | Fixed | Fixed |
Delay Time | 1 Sec, 8 Sec | 1 - 8 Sec |
Function | On-Delay, Off-Delay | On-Delay, Off-Delay |
Mounting Type | Chassis Mount | Chassis Mount |
Relay Type | Solid State Relay | Solid State Relay |
Termination Style | Quick Connect - 0.250" (6.3mm) | Quick Connect - 0.250" (6.3mm) |
Timing Adjustment Method | Fixed | Fixed |
Timing Initiate Method | Trigger Signal, Input Voltage | Trigger Signal, Input Voltage |
Voltage - Supply | 24 VAC | 24 VAC |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
CT1S8 Series
ON/OFF TIMING MODULE
Part | Function | Termination Style | Timing Initiate Method | Delay Time | Delay Time | Mounting Type | Relay Type | Voltage - Supply | Timing Adjustment Method |
---|---|---|---|---|---|---|---|---|---|
LITTELFUSE CT1S8 | |||||||||
LITTELFUSE CT1S8 | |||||||||
LITTELFUSE CT1S8 | Off-Delay, On-Delay | Quick Connect - 0.250" (6.3mm) | Input Voltage, Trigger Signal | Fixed | 1 Sec, 8 Sec | Chassis Mount | Solid State Relay | 24 VAC | Fixed |
Description
General part information
CT1S8 Series
The CT Series combines a delay-on-make and delay-on-break time delay into one unit and may be used to control fan delays in heating and/or cooling equipment. The CT includes bypass circuitry to allow it to operate with cooling anticipators ? 3000 ohms. It is designed to operate in 24VAC control circuits. Several CT modules may be combined to provide sequencing on of any number of loads and sequencing off of the same loads, such as electric heating elements. Operation (Delay-on-Make/Delay-on-Break) Forced Air Heating or Air Conditioning (as shown): When the thermostat closes, the compressor relay is immediately energized. At the end of a fixed delay-on-make delay (T1), the fan relay is energized. When the thermostat opens, the compressor relay is de-energized and the delay-on-break delay is initiated. On completion of the fixed delay-on- break delay (T2) the fan relay is de-energized. If the thermostat is reclosed during the delay-on-break delay, the delay-on-break delay is reset and the fan relay remains energized. If the thermostat is closed when input voltage is applied, the delay-on-make delay (T1) begins as normal.Reset: Removing input voltage resets the output and time delays.
Documents
Technical documentation and resources