Technical Specifications

Parameters and characteristics commom to parts in this series

SpecificationCT1S8CT1S8 Series
--
Delay TimeFixedFixed
Delay Time1 Sec, 8 Sec1 - 8 Sec
FunctionOn-Delay, Off-DelayOn-Delay, Off-Delay
Mounting TypeChassis MountChassis Mount
Relay TypeSolid State RelaySolid State Relay
Termination StyleQuick Connect - 0.250" (6.3mm)Quick Connect - 0.250" (6.3mm)
Timing Adjustment MethodFixedFixed
Timing Initiate MethodTrigger Signal, Input VoltageTrigger Signal, Input Voltage
Voltage - Supply24 VAC24 VAC

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$
DigikeyBulk 1$ 57.94
10$ 54.89
30$ 51.84
50$ 48.79
100$ 45.74
NewarkEach 10$ 56.27
25$ 50.58
50$ 46.23
100$ 45.22
250$ 43.88

CT1S8 Series

ON/OFF TIMING MODULE

PartFunctionTermination StyleTiming Initiate MethodDelay TimeDelay TimeMounting TypeRelay TypeVoltage - SupplyTiming Adjustment Method
LITTELFUSE
CT1S8
LITTELFUSE
CT1S8
LITTELFUSE
CT1S8
Off-Delay, On-Delay
Quick Connect - 0.250" (6.3mm)
Input Voltage, Trigger Signal
Fixed
1 Sec, 8 Sec
Chassis Mount
Solid State Relay
24 VAC
Fixed

Description

General part information

CT1S8 Series

The CT Series combines a delay-on-make and delay-on-break time delay into one unit and may be used to control fan delays in heating and/or cooling equipment. The CT includes bypass circuitry to allow it to operate with cooling anticipators ? 3000 ohms. It is designed to operate in 24VAC control circuits. Several CT modules may be combined to provide sequencing on of any number of loads and sequencing off of the same loads, such as electric heating elements. Operation (Delay-on-Make/Delay-on-Break) Forced Air Heating or Air Conditioning (as shown): When the thermostat closes, the compressor relay is immediately energized. At the end of a fixed delay-on-make delay (T1), the fan relay is energized. When the thermostat opens, the compressor relay is de-energized and the delay-on-break delay is initiated. On completion of the fixed delay-on- break delay (T2) the fan relay is de-energized. If the thermostat is reclosed during the delay-on-break delay, the delay-on-break delay is reset and the fan relay remains energized. If the thermostat is closed when input voltage is applied, the delay-on-make delay (T1) begins as normal.Reset: Removing input voltage resets the output and time delays.