NLP65 Series
Manufacturer: ARTESYN / Advanced Energy
AC/DC CONVERTER 5V 24V 60W
| Part | Minimum Load Required | Features | Efficiency | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Operating Temperature (Max) | Operating Temperature (Min) | Voltage - Isolation | Type | Number of Outputs | Approval Agency | Current - Output 2 | Voltage - Output 2 | Applications | Mounting Type | Current - Output 1 | Power (Watts) | Voltage - Output 1 | Size / Dimension Height | Size / Dimension Length | Size / Dimension Width | Current - Output 3 | Voltage - Output 3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ARTESYN / Advanced Energy | Yes | DC Input Capable Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 3 kV | Open Frame | 2 | CE | 2 A | 24 V | ITE (Commercial) | Chassis Mount | 7 A | 60 W 70 W | 5 V | 1.26 in | 5 in | 3 in | ||
ARTESYN / Advanced Energy | Yes | DC Input Capable Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 3 kV | Open Frame | 3 | CE | 2.5 A | 12 V | ITE (Commercial) | Chassis Mount | 7.5 A | 60 W 70 W | 5 V | 1.26 in | 5 in | 3 in | 650 mA | -12 V |
ARTESYN / Advanced Energy | Yes | Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 4000 Vpk | Open Frame | 1 | Medical | Chassis Mount | 2.7 A | 63 W 75 W | 24 V | 1.26 in | 5 in | 3 in | |||||
ARTESYN / Advanced Energy | Yes | DC Input Capable Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 3 kV | Open Frame | 2 | CE | 2.5 A | 12 V | ITE (Commercial) | Chassis Mount | 7 A | 60 W 70 W | 5 V | 1.26 in | 5 in | 3 in | ||
ARTESYN / Advanced Energy | Yes | DC Input Capable Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 3 kV | Open Frame | 1 | CE | ITE (Commercial) | Chassis Mount | 5.4 A | 60 W 70 W | 12 V | 1.26 in | 5 in | 3 in | ||||
ARTESYN / Advanced Energy | Yes | DC Input Capable Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 3 kV | Open Frame | 1 | CE | ITE (Commercial) | Chassis Mount | 5.4 A | 60 W 70 W | 12 V | 1.26 in | 5 in | 3 in | ||||
ARTESYN / Advanced Energy | Yes | DC Input Capable Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 3 kV | Open Frame | 1 | CE | ITE (Commercial) | Chassis Mount | 2.7 A | 60 W 70 W | 24 V | 1.26 in | 5 in | 3 in | ||||
ARTESYN / Advanced Energy | Yes | Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 4000 Vpk | Open Frame | 2 | 2 A | 24 V | Medical | Chassis Mount | 7 A | 63 W 75 W | 5 V | 1.26 in | 5 in | 3 in | |||
ARTESYN / Advanced Energy | Yes | Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 4000 Vpk | Open Frame | 1 | Medical | Chassis Mount | 5.4 A | 63 W 75 W | 12 V | 1.26 in | 5 in | 3 in | |||||
ARTESYN / Advanced Energy | Yes | DC Input Capable Universal Input | 72 % | 85 VAC | 264 V | 70 °C | 0 °C | 3 kV | Open Frame | 3 | CE | 2.2 A | 15 V | ITE (Commercial) | Chassis Mount | 7.5 A | 60 W 70 W | 5 V | 1.26 in | 5 in | 3 in | 650 mA | -15 V |