TEL 12 Series
Manufacturer: Traco Power
12 WATT DC/DC CONVERTER, INDUSTR
| Part | Voltage - Output 1 | Voltage - Input (Max) | Voltage - Input (Min) | Size / Dimension Width | Size / Dimension Height | Size / Dimension Length | Power (Watts) | Mounting Type | Operating Temperature (Min) | Operating Temperature (Max) | Efficiency | Features | Type | Number of Outputs | Package Leads | Package Name | Voltage - Output 2 | Approval Agency | Applications | Voltage - Isolation | Current - Output (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Traco Power | 15 V | 36 V | 18 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 87 % | Baseplate | Isolated Module | 2 | 5 Leads | 16-DIP Module | -15 V | CB cURus | ITE (Commercial) | 1800 VAC | 400 mA |
Traco Power | 15 V | 36 V | 18 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 88 % | Baseplate | Isolated Module | 1 | 5 Leads | 16-DIP Module | CB cURus | ITE (Commercial) | 1800 VAC | 800 mA | |
Traco Power | 15 V | 75 V | 18 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 87 % | Baseplate | Isolated Module | 2 | 5 Leads | 16-DIP Module | -15 V | CB cURus | ITE (Commercial) | 1800 VAC | 400 mA |
Traco Power | 12 V | 36 V | 9 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 87 % | Baseplate | Isolated Module | 2 | 5 Leads | 16-DIP Module | -12 V | CB cURus | ITE (Commercial) | 1800 VAC | 500 mA |
Traco Power | 24 V | 75 V | 18 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 88 % | Baseplate | Isolated Module | 1 | 5 Leads | 16-DIP Module | CB cURus | ITE (Commercial) | 1800 VAC | 500 mA | |
Traco Power | 15 V | 75 V | 18 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 88 % | Baseplate | Isolated Module | 1 | 5 Leads | 16-DIP Module | CB cURus | ITE (Commercial) | 1800 VAC | 800 mA | |
Traco Power | 24 V | 75 V | 36 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 88 % | Baseplate | Isolated Module | 1 | 5 Leads | 16-DIP Module | CB cURus | ITE (Commercial) | 1800 VAC | 500 mA | |
Traco Power | 12 V | 36 V | 9 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 87 % | Baseplate | Isolated Module | 1 | 5 Leads | 16-DIP Module | CB cURus | ITE (Commercial) | 1800 VAC | 1 A | |
Traco Power | 24 V | 18 V | 9 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 88 % | Baseplate | Isolated Module | 1 | 5 Leads | 16-DIP Module | CB cURus | ITE (Commercial) | 1800 VAC | 500 mA | |
Traco Power | 12 V | 75 V | 36 V | 0.54 in | 0.4 in | 0.94 in | 12 W | Through Hole | -40 °C | 85 °C | 87 % | Baseplate | Isolated Module | 2 | 5 Leads | 16-DIP Module | -12 V | CB cURus | ITE (Commercial) | 1800 VAC | 500 mA |