AC/DC CONVERTER 24V 50W
| Part | Power (Watts) | Voltage - Input [Max] | Voltage - Input [Min] | Features | Type | Applications | Voltage - Isolation | Voltage - Output 1 | Efficiency | Standard Number | Approval Agency | Operating Temperature [Max] | Operating Temperature [Min] | Number of Outputs | Current - Output 1 | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [x] | Mounting Type | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CUI Inc.  | 50 W  | 277 VAC  | 90 VAC  | Adjustable Output  Universal Input  | Open Frame  | ITE (Commercial)  | 3000 V  | 24 V  | 89 %  | 55024  60950-1  61000-3-2  61000-3-3  61000-6-1  61000-6-3  61204-3  | CB Scheme  EN  FCC  IEC  SIQ  TUV  UL  | 60 °C  | -20 °C  | 1  | 2.1 A  | 2 in  | 101.6 mm  | 1.32 in  | 33.6 mm  | 50.8 mm  | 4 in  | Chassis Mount  | 
CUI Inc.  | 50 W  | 277 VAC  | 90 VAC  | Adjustable Output  Universal Input  | Open Frame  | ITE (Commercial)  | 3000 V  | 12 V  | 87 %  | 55024  60950-1  61000-3-2  61000-3-3  61000-6-1  61000-6-3  61204-3  | CB Scheme  EN  FCC  IEC  SIQ  TUV  UL  | 60 °C  | -20 °C  | 1  | 4.2 A  | 2 in  | 101.6 mm  | 1.32 in  | 33.6 mm  | 50.8 mm  | 4 in  | Chassis Mount  | 
CUI Inc.  | 50 W  | 277 VAC  | 90 VAC  | Adjustable Output  Universal Input  | Open Frame  | ITE (Commercial)  | 3000 V  | 15 V  | 88 %  | 55024  60950-1  61000-3-2  61000-3-3  61000-6-1  61000-6-3  61204-3  | CB Scheme  EN  FCC  IEC  SIQ  TUV  UL  | 60 °C  | -20 °C  | 1  | 3.4 A  | 2 in  | 101.6 mm  | 1.32 in  | 33.6 mm  | 50.8 mm  | 4 in  | Chassis Mount  | 
CUI Inc.  | 33 W  | 277 VAC  | 90 VAC  | Adjustable Output  Universal Input  | Open Frame  | ITE (Commercial)  | 3000 V  | 5 V  | 55024  60950-1  61000-3-2  61000-3-3  61000-6-1  61000-6-3  61204-3  | CB Scheme  EN  FCC  IEC  SIQ  TUV  UL  | 60 °C  | -20 °C  | 1  | 6.67 A  | 2 in  | 101.6 mm  | 1.32 in  | 33.6 mm  | 50.8 mm  | 4 in  | Chassis Mount  | |
CUI Inc.  | 50 W  | 264 VAC  | 90 VAC  | Universal Input  | Open Frame  | ITE (Commercial)  | 3000 V  | 24 V  | 89 %  | 55024  55032 Class B  61000-3-2  61000-3-3  62368-1  | CB Scheme  CE  EN  FCC  IEC  SIQ  TUV  UL  | 70 °C  | -20 °C  | 1  | 2.1 A  | Chassis Mount  | ||||||
CUI Inc.  | 50 W  | 264 VAC  | 90 VAC  | Universal Input  | Open Frame  | ITE (Commercial)  | 3000 V  | 12 V  | 87 %  | 55024  55032 Class B  61000-3-2  61000-3-3  62368-1  | CB Scheme  CE  EN  FCC  IEC  SIQ  TUV  UL  | 70 °C  | -20 °C  | 1  | 4.2 A  | Chassis Mount  | ||||||
CUI Inc.  | 51 W  | 264 VAC  | 90 VAC  | Universal Input  | Open Frame  | ITE (Commercial)  | 3000 V  | 15 V  | 88 %  | 55024  55032 Class B  61000-3-2  61000-3-3  62368-1  | CB Scheme  CE  EN  FCC  IEC  SIQ  TUV  UL  | 70 °C  | -20 °C  | 1  | 3.4 A  | Chassis Mount  |