AC/DC DIN RAIL SUPPLY 9V 5W
| Part | Standard Number | Input Type | Features | Power (Watts) | Minimum Load Required | Size / Dimension [x] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Applications | Voltage - Output 1 | Number of Outputs | Operating Temperature [Min] | Operating Temperature [Max] | AC Voltage - Input [Min] | AC Voltage - Input [Max] | Efficiency | DC Voltage - Input (Max) [Max] | DC Voltage - Input (Min) [Min] | Approval Agency | Voltage - Isolation | Current - Output (Max) [Max] | Load Regulation | Voltage - Input [Min] | Voltage - Input [Max] | Weight | Weight | Package / Case | Type | Line Regulation | Mounting Type | Current - Output 1 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
aimtec  | 60601-1  | AC or DC  | Universal Input  | 5 W  | 1.02 in  | 25.9 mm  | 23.1 mm  | 2.99 in  | 0.91 in  | 75.9 mm  | Medical  | 9 V  | 1  | -25 °C  | 70 °C  | 85 VAC  | 264 VAC  | 78 %  | 370 V  | 100 V  | cULus  cURus  | 4000 V  | 550 mA  | |||||||||||
aimtec  | Universal Input  | 5 W  | 2.03 in  | 51.5 mm  | 28 mm  | 0.7 "  | 1.1 in  | 17.8 mm  | ITE (Commercial)  Medical  | 5 V  | 1  | -40 °C  | 80 ¯C  | 74 %  | CB  CE  cURus  | 1 A  | 1 %  | 90 VAC  | 264 VAC  | 30 g  | 0.066 lb  | 5-DIP Module  | Enclosed  | 1 %  | Through Hole  | |||||||||
aimtec  | Universal Input  | 5 W  | 2.03 in  | 51.5 mm  | 28 mm  | 0.7 "  | 1.1 in  | 17.8 mm  | ITE (Commercial)  Medical  | 24 V  | 1  | -40 °C  | 80 ¯C  | 76 %  | CB  CE  cURus  | 210 mA  | 1 %  | 90 VAC  | 264 VAC  | 5-DIP Module  | Enclosed  | 1 %  | Through Hole  | |||||||||||
aimtec  | Universal Input  | 5 W  | 1.46 in  | 37 mm  | 24.5 mm  | 0.71 in  | 0.96 in  | 18 mm  | ITE (Commercial)  | 9 V  | 1  | 77 %  | 560 mA  | 1 %  | 85 VAC  100 V  | 264 VAC  370 VDC  | 25 g  | 0.055 lb  | 26-DIP Module  5 Leads  | Enclosed  | 0.5 %  | Through Hole  | ||||||||||||
aimtec  | Universal Input  | 5 W  | 1.46 in  | 37 mm  | 24.9 mm  | 0.71 in  | 0.97 "  | 18 mm  | ITE (Commercial)  | 24 V  | 1  | -40 °C  | 70 °C  | 81 %  | 4000 V  | 85 VAC  100 V  | 264 VAC  370 VDC  | Enclosed  | Chassis Mount  | 210 mA  | ||||||||||||||
aimtec  | Universal Input  | 5 W  | 2.03 in  | 51.5 mm  | 28 mm  | 0.7 "  | 1.1 in  | 17.8 mm  | ITE (Commercial)  Medical  | 5 V  | 1  | -40 °C  | 80 ¯C  | 74 %  | CB  CE  cURus  | 1 A  | 1 %  | 90 VAC  | 264 VAC  | 5-DIP Module  | Enclosed  | 1 %  | Through Hole  | |||||||||||
aimtec  | 5 W  | 2 in  | 50.8 mm  | 25.4 mm  | 0.6 "  | 25.4 mm  | 15.2 mm  | ITE (Commercial)  | 5 V  | 1  | -25 °C  | 70 °C  | 78 %  | CE  cULus  cURus  | 1 A  | 0.5 %  | 4-DIP Module  | Enclosed  | 0.5 %  | Through Hole  | ||||||||||||||
aimtec  | 60601-1  | Universal Input  | 2.99 in  | 76 mm  | 31.5 mm  | 0.94 in  | 1.24 in  | 24 mm  | Medical  | 24 V  | 1  | -25 °C  | 70 °C  | 83 %  | cULus  cURus  | 4000 V  | Enclosed  | Chassis Mount  | 230 mA  | |||||||||||||||
aimtec  | Universal Input  | 5 W  | 2.03 in  | 51.5 mm  | 28 mm  | 0.7 "  | 1.1 in  | 17.8 mm  | ITE (Commercial)  Medical  | 24 V  | 1  | -40 °C  | 80 ¯C  | 76 %  | CB  CE  cURus  | 210 mA  | 1 %  | 90 VAC  | 264 VAC  | 30 g  | 0.066 lb  | 5-DIP Module  | Enclosed  | 1 %  | Through Hole  | |||||||||
aimtec  | 5 W  | 2.03 in  | 51.5 mm  | 28.3 mm  | 0.7 "  | 1.11 in  | 17.8 mm  | ITE (Commercial)  | 12 V  | 1  | -40 °C  | 95 °C  | 76 %  | CB  CE  cURus  | 420 mA  | 1 %  | 90 VAC  130 VDC  | 305 VAC  430 VDC  | 30 g  | 0.066 lb  | 4-DIP Module  | Enclosed  | 1 %  | Through Hole  |