AMEL5 Series
Manufacturer: aimtec
AC/DC DIN RAIL SUPPLY 9V 5W
| Part | Minimum Load Required | Applications | Power (Watts) | Efficiency | Input Type | DC Voltage - Input (Max) | Approval Agency | AC Voltage - Input (Max) | AC Voltage - Input (Min) | Current - Output (Max) | DC Voltage - Input (Min) | Standard Number | Number of Outputs | Operating Temperature (Max) | Operating Temperature (Min) | Voltage - Output 1 | Features | Size / Dimension Height | Size / Dimension Width | Size / Dimension Length | Voltage - Isolation | Mounting Type | Package / Case | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Type | Line Regulation | Load Regulation (Percent) | Weight | Package Name | Package Leads | Voltage - Input (DC) Minimum | Voltage - Input (DC) Maximum | Current - Output 1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
aimtec | No | Medical | 5 W | 78 % | AC AC or DC DC | 370 V | cULus cURus | 264 VAC | 85 VAC | 550 mA | 100 V | 60601-1 | 1 | 70 °C | -25 °C | 9 V | Universal Input | 2.99 in | 0.91 in | 1.02 in | 4000 Vpk | |||||||||||||
aimtec | ITE (Commercial) Medical | 5 W | 74 % | CB CE cULus cURus EN IEC UL | 1 A | 60601-1 | 1 | 80 °C | -40 °C | 5 V | Universal Input | 0.7 in | 1.1 in | 2.03 in | Through Hole | 5-DIP Module | 90 V | 264 V | Enclosed | 1 % | 1 % | 0.066 lb | ||||||||||||
aimtec | ITE (Commercial) Medical | 5 W | 76 % | CB CE cURus | 210 mA | 1 | 80 °C | -40 °C | 24 V | Universal Input | 0.7 in | 1.1 in | 2.03 in | Through Hole | 5-DIP Module | 90 V | 264 V | Enclosed | 1 % | 1 % | ||||||||||||||
aimtec | ITE (Commercial) | 5 W | 77 % | cURus | 560 mA | 1 | 70 °C | -40 °C | 9 V | Universal Input | 0.71 in | 0.96 in | 1.46 in | Through Hole | 85 VAC | 264 V | Enclosed | 0.5 % | 1 % | 0.055 lb | 26-DIP Module | 5 Leads | 100 V | 370 V | ||||||||||
aimtec | ITE (Commercial) | 5 W | 81 % | cURus | 1 | 70 °C | -40 °C | 24 V | Universal Input | 0.71 in | 0.97 in | 1.46 in | 4000 Vpk | Chassis Mount | 85 VAC | 264 V | Enclosed | 100 V | 370 V | 210 mA | ||||||||||||||
aimtec | ITE (Commercial) Medical | 5 W | 74 % | CB CE cURus | 1 A | 1 | 80 °C | -40 °C | 5 V | Universal Input | 0.7 in | 1.1 in | 2.03 in | Through Hole | 5-DIP Module | 90 V | 264 V | Enclosed | 1 % | 1 % | ||||||||||||||
aimtec | ITE (Commercial) | 5 W | 78 % | CE cULus cURus | 1 A | 1 | 70 °C | -25 °C | 5 V | 0.6 in | 1 in | 2 in | Through Hole | 4-DIP Module | 85 VAC | 264 V | Enclosed | 0.5 % | 0.5 % | |||||||||||||||
aimtec | ITE (Commercial) | 5 W | 74 % | 550 mA | 1 | 70 °C | -40 °C | 9 V | 0.61 in | 2 in | 1 in | Through Hole | 4-DIP Module | 85 VAC | 305 VAC | Enclosed | 0.5 % | 1 % | 0.068 lb | |||||||||||||||
aimtec | No | Medical | 5.5 W | 83 % | cULus cURus | 60601-1 | 1 | 70 °C | -25 °C | 24 V | Universal Input | 0.94 in | 1.24 in | 2.99 in | 4000 Vpk | Chassis Mount | 85 VAC | 264 V | Enclosed | 230 mA | ||||||||||||||
aimtec | ITE (Commercial) Medical | 5 W | 76 % | CB CE cULus cURus EN IEC UL | 210 mA | 60601-1 | 1 | 80 °C | -40 °C | 24 V | Universal Input | 0.7 in | 1.1 in | 2.03 in | Through Hole | 5-DIP Module | 90 V | 264 V | Enclosed | 1 % | 1 % | 0.066 lb |