| Part | Voltage - Isolation | Efficiency | Mounting Type | Type | Voltage - Input (Max) | Current - Output (Max) | Approval Agency | Size / Dimension Width | Size / Dimension Height | Size / Dimension Length | Number of Outputs | Voltage - Input (Min) | Operating Temperature (Min) | Operating Temperature (Max) | Package Leads | Package Name | Voltage - Output 1 | Features | Power (Watts) | Applications | Package / Case | Standard Number | Voltage - Output 2 | Voltage - Output 1 (Min) | Voltage - Output 1 (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
aimtec | 1500 Vrns | 77 % | Through Hole | Isolated Module | 36 V | 200 mA | cURus | 0.37 in | 0.49 in | 0.87 in | 1 | 18 V | -40 °C | 100 °C | 7 Leads | 8-SIP 8-SIP Module | 5 V | Remote On/Off | 1 W | ITE (Commercial) | |||||
aimtec | 3 kV | 79 % | Through Hole | Isolated Module | 18 V | 111 mA | cULus cURus | 0.37 in | 0.49 in | 0.87 in | 1 | 9 V | -40 °C | 100 °C | 9 V | Remote On/Off | 1 mW | ITE (Commercial) | 8-SIP Module | ||||||
aimtec | 1000 Vrms | 69 % | Through Hole | Isolated Module | 9 V | 69 mA | CE cURus EN IEC UL | 0.36 in | 0.44 in | 0.86 in | 2 | 4.5 V | -40 °C | 85 °C | Remote On/Off | 1 W | ITE (Commercial) | 8-SIP Module | 62368-1 | -7.2 V | -7.2 V | 7.2 V | |||
aimtec | 3 kV | 77 % | Through Hole | Isolated Module | 36 V | 42 mA | cULus cURus | 0.37 in | 0.47 in | 0.87 in | 1 | 18 V | -40 °C | 100 °C | 24 V | Remote On/Off | 1 W | ITE (Commercial) | 8-SIP Module | ||||||
aimtec | 1000 Vrms | 70 % | Through Hole | Isolated Module | 9 V | 33 mA | CE cURus EN IEC UL | 0.36 in | 0.44 in | 0.86 in | 2 | 4.5 V | -40 °C | 85 °C | Remote On/Off | 1 W | ITE (Commercial) | 8-SIP Module | 62368-1 | -15 V | -15 V | 15 V | |||
aimtec | 1500 Vrns | 77 % | Through Hole | Isolated Module | 18 V | 200 mA | cULus cURus | 0.37 in | 0.47 in | 0.87 in | 1 | 9 V | -40 °C | 100 °C | 5 V | Remote On/Off | 1 W | ITE (Commercial) | 8-SIP Module | ||||||
aimtec | 3 kV | 76 % | Through Hole | Isolated Module | 9 V | 83 mA | cURus | 0.37 in | 0.49 in | 0.87 in | 1 | 4.5 V | -40 °C | 100 °C | 7 Leads | 8-SIP Module | 12 V | 996 mW | ITE (Commercial) | ||||||
aimtec | 3 kV | 72 % | Through Hole | Isolated Module | 9 V | 200 mA | cURus | 0.37 in | 0.49 in | 0.87 in | 1 | 4.5 V | -40 °C | 100 °C | 7 Leads | 8-SIP Module | 5 V | 1 W | ITE (Commercial) | ||||||
aimtec | 1000 Vrms | 72 % | Through Hole | Isolated Module | 36 V | 200 mA | CE cURus EN IEC UL | 0.36 in | 0.44 in | 0.86 in | 1 | 18 V | -40 °C | 85 °C | 7 Leads | 8-SIP Module | 5 V | 1 W | ITE (Commercial) | 62368-1 | |||||
aimtec | 1000 Vrms | 72 % | Through Hole | Isolated Module | 18 V | 200 mA | CE cURus EN IEC UL | 0.36 in | 0.44 in | 0.86 in | 1 | 9 V | -40 °C | 85 °C | 5 V | Remote On/Off | 1 W | ITE (Commercial) | 8-SIP Module | 62368-1 |