| Part | Voltage - Isolation | Size / Dimension Height | Size / Dimension Length | Size / Dimension Width | Efficiency | Type | Operating Temperature (Max) | Operating Temperature (Min) | Voltage - Output 1 | Mounting Type | Applications | Power (Watts) | Number of Outputs | Current - Output 1 | Features | Voltage - Input (AC) Minimum | Voltage - Input | Voltage - Input (AC) Maximum | Approval Agency | Minimum Load Required |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2.5 in | 92 % | Open Frame | 70 °C | -40 °C | 58 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 2.07 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2.5 in | 92 % | Open Frame | 70 °C | -40 °C | 58 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 2.07 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | No |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2 in | 88 % | Open Frame | 70 °C | -40 °C | 12 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 10 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2.5 in | 88 % | Open Frame | 70 °C | -40 °C | 15 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 8 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | No |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2.5 in | 92 % | Open Frame | 70 °C | -40 °C | 48 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 2.5 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | No |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2.5 in | 90 % | Open Frame | 70 °C | -40 °C | 24 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 5 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | No |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2 in | 90 % | Open Frame | 70 °C | -40 °C | 24 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 5 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2 in | 92 % | Open Frame | 70 °C | -40 °C | 48 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 2.5 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2.5 in | 88 % | Open Frame | 70 °C | -40 °C | 15 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 8 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | No |
Bel Fuse Inc. | 3 kV | 0.75 in | 4 in | 2.5 in | 90 % | Open Frame | 70 °C | -40 °C | 30 V | Chassis Mount | ITE (Commercial) | 120 W 180 W | 1 | 4 A | Adjustable Output PFC Standby Output Universal Input | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL |