MWLT60 Series
Manufacturer: Bel Fuse Inc.
AC/DC CNVRTR 5.2V 24V -12.8V 84W
| Part | Type | Number of Outputs | Operating Temperature (Max) | Operating Temperature (Min) | Power (Watts) | Efficiency | Mounting Type | Size / Dimension Length | Size / Dimension Width | Size / Dimension Height | Current - Output 3 | Voltage - Output 2 | Voltage - Output 1 | Voltage - Output 3 | Features | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Voltage - Isolation | Current - Output 2 | Approval Agency | Current - Output 1 | Applications | Minimum Load Required |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | Open Frame | 3 | 70 °C | -20 °C | 84 W | 85 % | Chassis Mount | 4 in | 2 in | 1.2 in | 500 mA | 24 V | 5.2 V | -12.8 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | 1.5 A | CE cUL NEMKO UL | 8 A | Medical | |
Bel Fuse Inc. | Open Frame | 3 | 70 °C | -20 °C | 86 W | 85 % | Chassis Mount | 4 in | 2 in | 1.2 in | 500 mA | 12.5 V | 5.2 V | -12.8 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | 3 A | CE cUL NEMKO UL | 8 A | Medical | Yes |
Bel Fuse Inc. | Open Frame | 3 | 70 °C | -20 °C | 42 W | 85 % | Chassis Mount | 4 in | 2 in | 1.2 in | 500 mA | 5.2 V | 3.3 V | -12.8 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | 3 A | CE cUL NEMKO UL | 6 A | Medical | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 65 W | 85 % | Chassis Mount | 4 in | 2 in | 1.12 in | 15 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | CE cUL NEMKO UL | 4.33 A | Medical | No | ||||
Bel Fuse Inc. | Open Frame | 3 | 70 °C | -20 °C | 86 W | 85 % | Chassis Mount | 4 in | 2 in | 1.2 in | 500 mA | 12.5 V | 5.2 V | -12.8 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | 3 A | CE cUL NEMKO UL | 8 A | Medical | |
Bel Fuse Inc. | Open Frame | 3 | 70 °C | -20 °C | 86 W | 85 % | Chassis Mount | 4 in | 2 in | 1.2 in | 500 mA | 14.6 V | 5.2 V | -14.8 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | 2.5 A | CE cUL NEMKO UL | 8 A | Medical | Yes |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 51 W | 85 % | Chassis Mount | 4 in | 2 in | 1.12 in | 5.1 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | CE cUL NEMKO UL | 10 A | Medical | No | ||||
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 65 W | 85 % | Chassis Mount | 4 in | 2 in | 1.12 in | 15 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | CE cUL NEMKO UL | 4.33 A | Medical | |||||
Bel Fuse Inc. | Open Frame | 3 | 70 °C | -20 °C | 84 W | 85 % | Chassis Mount | 4 in | 2 in | 1.2 in | 500 mA | 24 V | 5.2 V | -12.8 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | 1.5 A | CE cUL NEMKO UL | 8 A | Medical | Yes |
Bel Fuse Inc. | Open Frame | 3 | 70 °C | -20 °C | 42 W | 85 % | Chassis Mount | 4 in | 2 in | 1.2 in | 500 mA | 5.2 V | 3.3 V | -12.8 V | Adjustable Output Universal Input | 90 V | 264 V | 5.7 kV | 3 A | CE cUL NEMKO UL | 6 A | Medical | Yes |