MBC41 Series
Manufacturer: Bel Fuse Inc.
AC/DC CONVERTER 24V 40W
| Part | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Power (Watts) | Mounting Type | Applications | Operating Temperature (Max) | Operating Temperature (Min) | Current - Output (Max) | Features | Type | Package / Case | Efficiency | Approval Agency | Voltage - Output 1 | Number of Outputs | Size / Dimension Height | Size / Dimension Length | Size / Dimension Width | Load Regulation (Percent) | Line Regulation | Weight | Voltage - Isolation | Minimum Load Required | Current - Output 1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Through Hole | Medical | 70 °C | -40 °C | 1.67 A | Universal Input | Open Frame | 4-DIP Module | 85 % | CE cUL NEMKO UL | 24 V | 1 | 0.97 in | 3 in | 2 in | 1 % | 0.5 % | 0.221 lb | |||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Through Hole | Medical | 70 °C | -40 °C | 3.33 A | Universal Input | Open Frame | 4-DIP Module | 85 % | CE cUL NEMKO UL | 12 V | 1 | 0.97 in | 3 in | 2 in | ||||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 5 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | |||||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 24 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | Yes | 1.67 A | |||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 48 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | Yes | 830 mA | |||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 15 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | Yes | 2.67 A | |||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 30 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | Yes | 1.33 A | |||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 5 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | Yes | 5 A | |||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 12 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | Yes | 3.33 A | |||||
Bel Fuse Inc. | 85 VAC | 264 V | 40 W | Chassis Mount | Medical | 70 °C | -40 °C | Universal Input | Open Frame | 85 % | CE cUL NEMKO UL | 12 V | 1 | 0.97 in | 3 in | 2 in | 4000 Vpk | Yes | 3.33 A |