WLT150 Series
Manufacturer: Bel Fuse Inc.
AC/DC CONVERTER 5V 80W
| Part | Type | Number of Outputs | Operating Temperature (Max) | Operating Temperature (Min) | Minimum Load Required | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Voltage - Input (DC) Maximum | Voltage - Input (DC) Minimum | Approval Agency | Voltage - Isolation | Voltage - Output 1 | Current - Output 1 | Mounting Type | Features | Efficiency | Size / Dimension Width | Size / Dimension Length | Size / Dimension Height | Power (Watts) | Applications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | No | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 5 V | 16 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 80 W 100 W | ITE (Commercial) |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 24 V | 4.17 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | No | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 12 V | 8.33 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 5 V | 16 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 80 W 80 W | ITE (Commercial) | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | No | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 15 V | 6.67 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 15 V | 6.67 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 48 V | 2.08 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | No | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 15 V | 6.67 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 12 V | 8.33 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) | |
Bel Fuse Inc. | Open Frame | 1 | 70 °C | -20 °C | 90 V | 264 V | 390 V | 120 V | CB CE cUL NEMKO UL | 4242 V | 24 V | 4.17 A | Chassis Mount | Adjustable Output PFC Standby Output Universal Input | 86 % | 2 in | 4 in | 1.32 in | 100 W 150 W | ITE (Commercial) |