REM2 Series
Manufacturer: Recom Power
ISOLATED THROUGH HOLE DC/DC CONVERTER, MEDICAL, 1:1, 2 W, 2 OUTPUT, 5 V, 200 MA
| Part | Type | Voltage - Isolation | Package Leads | Package Name | Voltage - Input (Min) | Power (Watts) | Applications | Voltage - Output 2 | Voltage - Input (Max) | Voltage - Output 1 | Features | Mounting Type | Current - Output (Max) | Size / Dimension Length | Size / Dimension Width | Size / Dimension Height | Number of Outputs | Operating Temperature (Max) | Operating Temperature (Min) | Efficiency | Approval Agency | Current - Output (Max) Options |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recom Power | Isolated Module | 5.2 kV | 5 Leads | 8-SIP Module | 4.5 V | 2 w | ITE (Commercial) Medical | -5 V | 5.5 V | 5 V | OCP | Through Hole | 200 mA | 0.91 in | 0.31 in | 0.48 in | 2 | 95 °C | -40 °C | 82 % | CB cURus | |
Recom Power | Isolated Module | 5.2 kV | 4 Leads | 8-SIP Module | 4.5 V | 2 w | ITE (Commercial) Medical | 5.5 V | 5 V | OCP | Through Hole | 400 mA | 0.91 in | 0.31 in | 0.48 in | 1 | 95 °C | -40 °C | 79 % | CB cURus | ||
Recom Power | Isolated Module | 5.2 kV | 5 Leads | 8-SIP Module | 4.5 V | 2 w | ITE (Commercial) Medical | -3.3 V | 5.5 V | 3.3 V | OCP | Through Hole | 303 mA | 0.91 in | 0.31 in | 0.48 in | 2 | 95 °C | -40 °C | 79 % | CB cURus | |
Recom Power | Isolated Module | 5.2 kV | 5 Leads | 8-SIP Module | 10.8 V | 2 w | ITE (Commercial) Medical | -5 V | 13.2 V | 5 V | OCP | Through Hole | 200 mA | 0.91 in | 0.31 in | 0.48 in | 2 | 95 °C | -40 °C | 82 % | CB cURus | |
Recom Power | Isolated Module | 5.2 kV | 5 Leads | 8-SIP Module | 21.6 V | 2 w | ITE (Commercial) Medical | -12 V | 26.4 V | 12 V | OCP | Through Hole | 0.91 in | 0.31 in | 0.48 in | 2 | 95 °C | -40 °C | 85 % | CB cURus | 84mA | |
Recom Power | Isolated Module | 5.2 kV | 4 Leads | 8-SIP Module | 21.6 V | 2 w | ITE (Commercial) Medical | 26.4 V | 12 V | OCP | Through Hole | 167 mA | 0.91 in | 0.31 in | 0.48 in | 1 | 95 °C | -40 °C | 82 % | CB cURus | ||
Recom Power | Isolated Module | 5.2 kV | 5 Leads | 8-SIP Module | 13.5 V | 2 w | ITE (Commercial) Medical | -3.3 V | 16.5 V | 3.3 V | OCP | Through Hole | 303 mA | 0.91 in | 0.31 in | 0.48 in | 2 | 95 °C | -40 °C | 79 % | CB cURus | |
Recom Power | Isolated Module | 5.2 kV | 5 Leads | 8-SIP Module | 2.97 V | 2 w | ITE (Commercial) Medical | -5 V | 3.63 V | 5 V | OCP | Through Hole | 200 mA | 0.91 in | 0.31 in | 0.48 in | 2 | 95 °C | -40 °C | 82 % | CB cURus | |
Recom Power | Isolated Module | 5.2 kV | 4 Leads | 8-SIP Module | 2.97 V | 2 w | ITE (Commercial) Medical | 3.63 V | 5 V | OCP | Through Hole | 400 mA | 0.91 in | 0.31 in | 0.48 in | 1 | 95 °C | -40 °C | 79 % | CB cURus | ||
Recom Power | Isolated Module | 5.2 kV | 4 Leads | 8-SIP Module | 21.6 V | 2 w | ITE (Commercial) Medical | 26.4 V | 9 V | OCP | Through Hole | 222 mA | 0.91 in | 0.31 in | 0.48 in | 1 | 95 °C | -40 °C | 84 % | CB cURus |