XMS500 Series
Manufacturer: TDK Corporation
AC/DC OPEN FRAME POWER SUPPLY (PSU), MEDICAL, 1 OUTPUT, 500W, 250 W, 90V AC TO 264V AC, FIXED
| Part | Power (Watts) | Features | Current - Output 1 | Voltage - Output 1 | Type | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Applications | Voltage - Isolation | Operating Temperature (Max) | Operating Temperature (Min) | Number of Outputs | Efficiency | Mounting Type | Size / Dimension Width | Size / Dimension Height | Size / Dimension Length |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDK Corporation | 250 W 500 W | Universal Input | 20.8 A | 24 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4.21 in | 1.56 in | 7.09 in |
TDK Corporation | 250 W 500 W | Universal Input | 13.8 A | 36 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4 in | 1.46 in | 7.1 in |
TDK Corporation | 250 W 500 W | Universal Input | 13.8 A | 36 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4 in | 1.46 in | 7.1 in |
TDK Corporation | 250 W 500 W | Universal Input | 10.4 A | 48 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4.21 in | 1.56 in | 7.09 in |
TDK Corporation | 250 W 500 W | Universal Input | 10.4 A | 48 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4 in | 1.46 in | 7.1 in |
TDK Corporation | 500 W | Universal Input | 13.8 A | 36 V | Enclosed | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4.21 in | 1.85 in | 7.09 in |
TDK Corporation | 250 W 500 W | Universal Input | 13.8 A | 36 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4.21 in | 1.56 in | 7.09 in |
TDK Corporation | 250 W 500 W | Universal Input | 13.8 A | 36 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4.21 in | 1.56 in | 7.09 in |
TDK Corporation | 250 W 500 W | Universal Input | 10.4 A | 48 V | Open Frame | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4 in | 1.46 in | 7.1 in |
TDK Corporation | 500 W | Universal Input | 10.4 A | 48 V | Enclosed | 90 V | 264 V | ITE (Commercial) Medical | 4000 Vpk | 70 °C | 0 °C | 1 | 92 % | Chassis Mount | 4.21 in | 1.85 in | 7.09 in |