AC/DC CNVRT 3.3V 5.2V -12.8V 42W
Part | Power (Watts) | Operating Temperature [Min] | Operating Temperature [Max] | Type | Current - Output 3 | Efficiency | Mounting Type | Approval Agency | Voltage - Output 1 | Features | Current - Output 2 | Number of Outputs | Voltage - Output 3 | Voltage - Output 2 | Voltage - Isolation | Applications | Standard Number | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [z] | Minimum Load Required | Voltage - Input [Min] | Voltage - Input [Max] | Current - Output 1 | Size / Dimension [z] | Size / Dimension [y] |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EOS Power LFMWLT40-3003 | 42 W | -20 °C | 70 °C | Open Frame | 500 mA | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 3.3 V | Adjustable Output, Universal Input | 3 A | 3 | -12.8 V | 5.2 V | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 30.5 mm | 4 in | 50.8 mm | 1.2 " | 90 VAC | 264 VAC | 6 A | |||
EOS Power LFMWLT40-1000 | 41 W | -20 °C | 70 °C | Open Frame | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 5.1 V | Adjustable Output, Universal Input | 1 | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 4 in | 1.12 in | 90 VAC | 264 VAC | 8 A | 28.5 mm | 50.8 mm | |||||||
EOS Power LFMWLT40-1003 | 41 W | -20 °C | 70 °C | Open Frame | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 24 V | Adjustable Output, Universal Input | 1 | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 4 in | 1.12 in | 90 VAC | 264 VAC | 1.7 A | 28.5 mm | 50.8 mm | |||||||
EOS Power LFMWLT40-3001 | 62 W | -20 °C | 70 °C | Open Frame | 500 mA | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 5.2 V | Adjustable Output, Universal Input | 1 A | 3 | -12.8 V | 24 V | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 30.5 mm | 4 in | 50.8 mm | 1.2 " | 90 VAC | 264 VAC | 6 A | |||
EOS Power LFMWLT40-1002 | 41 W | -20 °C | 70 °C | Open Frame | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 15 V | Adjustable Output, Universal Input | 1 | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 4 in | 1.12 in | 90 VAC | 264 VAC | 2.7 A | 28.5 mm | 50.8 mm | |||||||
EOS Power LFMWLT40-3002 | 61 W | -20 °C | 70 °C | Open Frame | 500 mA | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 5.2 V | Adjustable Output, Universal Input | 1.5 A | 3 | -14.8 V | 14.6 V | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 30.5 mm | 4 in | 50.8 mm | 1.2 " | 90 VAC | 264 VAC | 6 A | |||
EOS Power LFMWLT40-1004 | 40 W | -20 °C | 70 °C | Open Frame | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 48 V | Adjustable Output, Universal Input | 1 | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 4 in | 1.12 in | 90 VAC | 264 VAC | 830 mA | 28.5 mm | 50.8 mm | |||||||
EOS Power LFMWLT40-1001 | 42 W | -20 °C | 70 °C | Open Frame | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 12 V | Adjustable Output, Universal Input | 1 | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 4 in | 1.12 in | 90 VAC | 264 VAC | 3.5 A | 28.5 mm | 50.8 mm | |||||||
EOS Power LFMWLT40-3000 | 63 W | -20 °C | 70 °C | Open Frame | 500 mA | 85 % | Chassis Mount | CE, cUL, NEMKO, UL | 5.2 V | Adjustable Output, Universal Input | 2 A | 3 | -12.8 V | 12.5 V | 5.7 kV | Medical | 60601-1 | 101.6 mm | 2 in | 30.5 mm | 4 in | 50.8 mm | 1.2 " | 90 VAC | 264 VAC | 6 A |