RP10-AW Series
Manufacturer: Recom Power
ISOLATED DC/DC CONVERTERS - THROUGH HOLE 10W 18-75VIN +/-12VOUT +/-416MA
| Part | Mounting Type | Voltage - Input (Max) | Voltage - Isolation | Size / Dimension Height | Size / Dimension Width | Size / Dimension Length | Control Features | Voltage - Input (Min) | Package / Case | Efficiency | Features | Voltage - Output 2 | Applications | Current - Output (Max) | Number of Outputs | Operating Temperature (Max) | Operating Temperature (Min) | Power (Watts) | Voltage - Output 1 | Approval Agency | Type | Package Leads | Package Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recom Power | Through Hole | 75 V | 1.6 kV | 0.39 in | 1 in | 1 in | Active Low Enable | 18 V | 6-DIP Module | 89 % | OCP OVP Remote On/Off SCP UVLO | -12 V | ITE (Commercial) | 416 mA | 2 | 81 °C | -40 °C | 10 W | 12 V | cURus EAC | Isolated Module | ||
Recom Power | Through Hole | 75 V | 1.6 kV | 0.39 in | 1 in | 1 in | Active Low Enable | 18 V | 6-DIP Module | 89 % | OCP OVP Remote On/Off SCP UVLO | -15 V | ITE (Commercial) | 333 mA | 2 | 81 °C | -40 °C | 10 W | 15 V | cURus EAC | Isolated Module | ||
Recom Power | Through Hole | 36 V | 1.6 kV | 0.39 in | 1 in | 1 in | Active High Enable | 9 V | 6-DIP Module | 90 % | OCP OVP Remote On/Off SCP UVLO | ITE (Commercial) | 416 mA | 1 | 81 °C | -40 °C | 10 W | 24 V | cURus EAC | Isolated Module | |||
Recom Power | Through Hole | 36 V | 1.6 kV | 0.39 in | 1 in | 1 in | 9 V | 91 % | OCP OVP SCP UVLO | ITE (Commercial) | 670 mA | 1 | 81 °C | -40 °C | 10 W | 15 V | cURus EAC | Isolated Module | 5 Leads | 6-DIP Module | |||
Recom Power | Through Hole | 36 V | 1.6 kV | 0.39 in | 1 in | 1 in | Active Low Enable | 9 V | 6-DIP Module | 87 % | OCP OVP Remote On/Off SCP UVLO | -5 V | ITE (Commercial) | 1 A | 2 | 81 °C | -40 °C | 10 W | 5 V | cURus EAC | Isolated Module | ||
Recom Power | Through Hole | 75 V | 1.6 kV | 0.65 in | 1 in | 1 in | 18 V | 90 % | OCP OVP SCP UVLO | ITE (Commercial) | 670 mA | 1 | 81 °C | -40 °C | 10 W | 15 V | cURus EAC | Isolated Module | 5 Leads | 6-DIP Module | |||
Recom Power | Through Hole | 36 V | 1.6 kV | 0.65 in | 1 in | 1 in | 9 V | 91 % | OCP OVP SCP UVLO | -15 V | ITE (Commercial) | 333 mA | 2 | 81 °C | -40 °C | 10 W | 15 V | cURus EAC | Isolated Module | 5 Leads | 6-DIP Module | ||
Recom Power | Through Hole | 36 V | 1.6 kV | 0.39 in | 1 in | 1 in | Active Low Enable | 9 V | 6-DIP Module | 89 % | OCP OVP Remote On/Off SCP UVLO | -12 V | ITE (Commercial) | 416 mA | 2 | 81 °C | -40 °C | 10 W | 12 V | cURus EAC | Isolated Module | ||
Recom Power | Through Hole | 36 V | 1.6 kV | 0.39 in | 1 in | 1 in | 9 V | 87 % | OCP OVP SCP UVLO | ITE (Commercial) | 2 A | 1 | 78 °C | -40 °C | 10 W | 5 V | cURus EAC | Isolated Module | 5 Leads | 6-DIP Module | |||
Recom Power | Through Hole | 36 V | 1.6 kV | 0.39 in | 1 in | 1 in | Active Low Enable | 9 V | 6-DIP Module | 90 % | OCP OVP Remote On/Off SCP UVLO | ITE (Commercial) | 416 mA | 1 | 81 °C | -40 °C | 10 W | 24 V | cURus EAC | Isolated Module |