RP10-EW Series
Manufacturer: Recom Power
ISOLATED DC/DC CONVERTERS - THROUGH HOLE 10W DC/DC 1.6KV REG 4:1 9-36VIN +/-5OUT
| Part | Size / Dimension Width | Size / Dimension Length | Size / Dimension Height | Features | Voltage - Input (Max) | Applications | Mounting Type | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Voltage - Output 2 | Type | Voltage - Output 1 | Operating Temperature (Max) | Operating Temperature (Min) | Voltage - Input (Min) | Efficiency | Control Features | Number of Outputs | Package / Case |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP Remote On/Off SCP | 36 V | ITE (Commercial) | Through Hole | 1 A | 10 W | 1.6 kV | -5 V | Isolated Module | 5 V | 85 °C | -25 °C | 9 V | 80 % | Active Low Enable | 2 | 6-DIP Module |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP Remote On/Off SCP | 75 V | ITE (Commercial) | Through Hole | 416 mA | 10 W | 1.6 kV | -12 V | Isolated Module | 12 V | 85 °C | -40 °C | 18 V | 78 % | Active High Enable | 2 | 6-DIP Module |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP Remote On/Off SCP | 75 V | ITE (Commercial) | Through Hole | 333 mA | 10 W | 1.6 kV | -15 V | Isolated Module | 15 V | 85 °C | -40 °C | 18 V | 81 % | Active Low Enable | 2 | 6-DIP Module |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP Remote On/Off SCP | 75 V | ITE (Commercial) | Through Hole | 2 A | 10 W | 1.6 kV | Isolated Module | 5 V | 85 °C | -25 °C | 18 V | 80 % | Active Low Enable | 1 | 6-DIP Module | |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP SCP | 75 V | ITE (Commercial) | Through Hole | 1 A | 10 W | 1.6 kV | -5 V | Isolated Module | 5 V | 85 °C | -25 °C | 18 V | 81 % | 2 | 6-DIP Module | |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP Remote On/Off SCP | 36 V | ITE (Commercial) | Through Hole | 670 mA | 10 W | 1.6 kV | Isolated Module | 15 V | 85 °C | -25 °C | 9 V | 80 % | Active High Enable | 1 | 6-DIP Module | |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP Remote On/Off SCP | 36 V | ITE (Commercial) | Through Hole | 1 A | 10 W | 1.6 kV | -5 V | Isolated Module | 5 V | 85 °C | -25 °C | 9 V | 80 % | Active High Enable | 2 | 6-DIP Module |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP SCP | 36 V | ITE (Commercial) | Through Hole | 333 mA | 10 W | 1.6 kV | -15 V | Isolated Module | 15 V | 85 °C | -25 °C | 9 V | 80 % | 2 | 6-DIP Module | |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP Remote On/Off SCP | 36 V | ITE (Commercial) | Through Hole | 2 A | 10 W | 1.6 kV | Isolated Module | 5 V | 85 °C | -25 °C | 9 V | 80 % | Active High Enable | 1 | 6-DIP Module | |
Recom Power | 1 in | 2 in | 0.4 in | OCP OVP SCP | 36 V | ITE (Commercial) | Through Hole | 1 A | 10 W | 1.6 kV | -5 V | Isolated Module | 5 V | 85 °C | -25 °C | 9 V | 80 % | 2 | 6-DIP Module |