MULP275 Series
Manufacturer: Bel Fuse Inc.
AC/DC CONVERTER 12V 160W
| Part | Number of Outputs | Minimum Load Required | Type | Size / Dimension Length | Size / Dimension Height | Size / Dimension Width | Voltage - Output 1 | Voltage - Input (AC) Minimum | Voltage - Input | Voltage - Input (AC) Maximum | Voltage - Isolation | Approval Agency | Applications | Mounting Type | Current - Output 1 | Power (Watts) | Efficiency | Operating Temperature (Max) | Operating Temperature (Min) | Features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | 1 | No | Open Frame | 5 in | 0.75 in | 3 in | 12 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 13.33 A | 160 W 275 W | 88 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input |
Bel Fuse Inc. | 1 | No | Open Frame | 5 in | 0.75 in | 3 in | 12 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 13.33 A | 160 W 275 W | 88 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input |
Bel Fuse Inc. | 1 | No | Open Frame | 5 in | 0.75 in | 3 in | 30 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 5.33 A | 160 W 275 W | 90 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input |
Bel Fuse Inc. | 1 | No | Open Frame | 5 in | 0.75 in | 3.5 in | 15 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 10.66 A | 160 W 275 W | 88 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input |
Bel Fuse Inc. | 1 | Open Frame | 5 in | 0.75 in | 3 in | 12 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 13.33 A | 160 W 275 W | 88 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input | |
Bel Fuse Inc. | 1 | No | Open Frame | 5 in | 0.75 in | 3.5 in | 30 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 5.33 A | 160 W 275 W | 90 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input |
Bel Fuse Inc. | 1 | Open Frame | 5 in | 0.75 in | 3.5 in | 48 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 3.33 A | 160 W 275 W | 92 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input | |
Bel Fuse Inc. | 1 | Open Frame | 5 in | 0.75 in | 3 in | 30 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 5.33 A | 160 W 275 W | 90 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input | |
Bel Fuse Inc. | 1 | No | Open Frame | 5 in | 0.75 in | 3 in | 15 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 10.66 A | 160 W 275 W | 88 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input |
Bel Fuse Inc. | 1 | Open Frame | 5 in | 0.75 in | 3.5 in | 30 V | 80 V | 390 VDC | 264 V | 4000 Vpk | CB CE cUL NEMKO UL | Medical | Chassis Mount | 5.33 A | 160 W 275 W | 90 % | 70 °C | -40 °C | Adjustable Output PFC Standby Output Universal Input |