CUS600M Series
Manufacturer: TDK Corporation
AC/DC ENCLOSED POWER SUPPLY (PSU), ITE & MEDICAL, 1 OUTPUTS, 400.8 W, 12 V, 33.4 A
| Part | Standard Number | Voltage - Output 1 | Number of Outputs | Operating Temperature (Max) | Operating Temperature (Min) | Efficiency | Size / Dimension Height | Size / Dimension Length | Size / Dimension Width | Approval Agency | Power (Watts) | Voltage - Input (AC) Maximum | Voltage - Input (AC) Minimum | Applications | Mounting Type | Type | Features | Current - Output 1 | Voltage - Isolation | Minimum Load Required | Voltage - Output 6 | Voltage - Output 3 | Voltage - Output 5 | Current - Output 4 | Current - Output 6 | Current - Output 3 | Current - Output 5 | Voltage - Output 4 | Current - Output 2 | Voltage - Output 2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDK Corporation | 60601-1 60950-1 62368-1 | 12 V | 1 | 70 °C | -20 °C | 96 % | 1.67 in | 6.18 in | 3.35 in | CE | 401 W 600 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Enclosed | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 33.4 A | 4000 Vpk | No | ||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 48 V | 1 | 70 °C | -20 °C | 96 % | 1.34 in | 5 in | 3 in | CE | 403 W 605 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Open Frame | Remote On/Off Remote Sense Standby Output Universal Input | 8.4 A | 4000 Vpk | |||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 24 V | 6 | 70 °C | -20 °C | 96 % | 1.46 in | 5 in | 3 in | CE | 401 W 600 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Open Frame | Adjustable Output Remote On/Off Remote Sense Standby Output | 25 A | 4000 Vpk | 24 V | 24 V | 24 V | 25 A | 25 A | 25 A | 25 A | 24 V | 25 A | 24 V | |
TDK Corporation | 60601-1 60950-1 62368-1 | 19 V | 1 | 70 °C | -20 °C | 96 % | 1.67 in | 6.18 in | 3.35 in | CE | 401 W 600 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Enclosed | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 21.1 A | 4000 Vpk | No | ||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 48 V | 1 | 70 °C | -20 °C | 96 % | 1.67 in | 6.18 in | 3.35 in | CE | 403 W 605 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Enclosed | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 8.4 A | 4000 Vpk | No | ||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 24 V | 1 | 70 °C | -20 °C | 96 % | 1.67 in | 6.18 in | 3.35 in | CE | 401 W 600 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Enclosed | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 16.7 A | 4000 Vpk | |||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 32 V | 1 | 70 °C | -20 °C | 96 % | 1.67 in | 6.18 in | 3.35 in | CE | 400 W 602 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Enclosed | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 12.5 A | 4000 Vpk | No | ||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 12 V | 1 | 70 °C | -20 °C | 96 % | 1.34 in | 5 in | 3 in | CE | 401 W 600 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Open Frame | Remote On/Off Remote Sense Standby Output Universal Input | 33.4 A | 4000 Vpk | No | ||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 32 V | 1 | 70 °C | -20 °C | 96 % | 1.34 in | 5 in | 3 in | CE | 400 W 602 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Open Frame | Remote On/Off Remote Sense Standby Output Universal Input | 12.5 A | 4000 Vpk | |||||||||||
TDK Corporation | 60601-1 60950-1 62368-1 | 28 V | 1 | 70 °C | -20 °C | 96 % | 1.67 in | 6.18 in | 3.35 in | CE | 400 W 602 W | 265 VAC | 85 VAC | ITE (Commercial) Medical | Chassis Mount | Enclosed | Adjustable Output Remote On/Off Remote Sense Standby Output Universal Input | 14.3 A | 4000 Vpk | No |