RP90Q-RW Series
Manufacturer: Recom Power
ISOLATED DC/DC CONVERTERS - THROUGH HOLE 90W 16.5-75VIN 12VOUT 7.5A
| Part | Power (Watts) | Features | Package / Case | Voltage - Output 1 | Efficiency | Package Name | Size / Dimension Width | Size / Dimension Height | Size / Dimension Length | Operating Temperature (Min) | Operating Temperature (Max) | Voltage - Input (Max) | Number of Outputs | Type | Mounting Type | Applications | Voltage - Isolation | Voltage - Input (Min) | Current - Output (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recom Power | 90 W | OCP OTP OVP SCP UVLO | Quarter Brick | 12 V | 89 % | Quarter Brick | 1.45 in | 0.5 in | 2.28 in | -40 °C | 100 °C | 75 V | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 2.25 kV | 16.5 V | 7.5 A |
Recom Power | 84 W | OCP OTP OVP SCP UVLO | Quarter Brick | 12 V | 89 % | Quarter Brick | 1.45 in | 0.5 in | 2.28 in | -40 °C | 100 °C | 160 VDC | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 3 kV | 40 V | 7 A |
Recom Power | 90 W | OCP OTP OVP SCP UVLO | Quarter Brick | 12 V | 89 % | Quarter Brick | 1.45 in | 0.74 in | 2.28 in | -40 °C | 100 °C | 36 V | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 2.25 kV | 9 V | 7.5 A |
Recom Power | 90 W | OCP OTP OVP SCP UVLO | Quarter Brick | 5 V | 89 % | Quarter Brick | 1.45 in | 0.5 in | 2.28 in | -40 °C | 100 °C | 36 V | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 2.25 kV | 9 V | 18 A |
Recom Power | 89 W | OCP OTP OVP SCP UVLO | Quarter Brick | 24 V | 89 % | Quarter Brick | 1.45 in | 0.74 in | 2.28 in | -40 °C | 100 °C | 36 V | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 2.25 kV | 9 V | 3.7 A |
Recom Power | 90 W | OCP OTP OVP SCP UVLO | Quarter Brick | 5 V | 89 % | Quarter Brick | 1.45 in | 0.74 in | 2.28 in | -40 °C | 100 °C | 75 V | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 2.25 kV | 16.5 V | 18 A |
Recom Power | 90 W | OCP OTP OVP SCP UVLO | Quarter Brick | 12 V | 89 % | Quarter Brick | 1.45 in | 0.74 in | 2.28 in | -40 °C | 100 °C | 75 V | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 2.25 kV | 16.5 V | 7.5 A |
Recom Power | 87 W | OCP OTP OVP SCP UVLO | Quarter Brick | 48 V | 89 % | Quarter Brick | 1.45 in | 0.5 in | 2.28 in | -40 °C | 100 °C | 160 VDC | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 3 kV | 40 V | 1.8 A |
Recom Power | 89 W | OCP OTP OVP SCP UVLO | Quarter Brick | 24 V | 90 % | Quarter Brick | 1.45 in | 0.74 in | 2.28 in | -40 °C | 100 °C | 75 V | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 2.25 kV | 16.5 V | 3.7 A |
Recom Power | 85 W | OCP OTP OVP SCP UVLO | Quarter Brick | 5 V | 89 % | Quarter Brick | 1.45 in | 0.74 in | 2.28 in | -40 °C | 100 °C | 160 VDC | 1 | Isolated Module | Through Hole | ITE (Commercial) Railway | 3 kV | 40 V | 17 A |