UT Series
Manufacturer: Laird Thermal Systems, Inc.
THERMOELECTRIC PELTIER MODULES THERMOELECTRIC COOLER, HIGH HEAT PUMP DENSITY, EPOXY PERIMETER SEAL, 63.8 W
| Part | Operating Temperature | Size / Dimension Shape | Size / Dimension Width | Size / Dimension Length | Height | Features | Voltage - Max | Resistance | Maximum Power Dissipation (Qmax) | Current - Max | Number of Stages | Delta Tmax |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Laird Thermal Systems, Inc. | 80 °C | Rectangular | 24.56 mm | 26.92 mm | 1.96 mm | Epoxy Lead Wires Sealed | 14.4 V | 1.68 Ohms | 69 W | 7.9 A | 1 | 69 °C |
Laird Thermal Systems, Inc. | ||||||||||||
Laird Thermal Systems, Inc. | 80 °C | Rectangular | 30 mm | 34 mm | 2.56 mm | Epoxy Lead Wires Sealed | 14.5 V | 1.67 Ohms | 69 W | 8 A | 1 | 67 °C |
Laird Thermal Systems, Inc. | 80 °C | Rectangular | 30 mm | 34 mm | 2.41 mm | Lapped Lead Wires | 14.5 V | 1.2 Ohm | 95.4 W | 11.1 A | 1 | 67 °C |
Laird Thermal Systems, Inc. | 80 °C | Rectangular | 30 mm | 34 mm | 2.56 mm | Lead Wires Non-Sealed | 14.5 V | 1.67 Ohms | 69 W | 8 A | 1 | 67 °C |