AC/DC OPEN FRAME POWER SUPPLY (PSU), MEDICAL, 1 OUTPUT, 500W, 250 W, 90V AC TO 264V AC, FIXED
| Part | Operating Temperature [Max] | Operating Temperature [Min] | Number of Outputs | Mounting Type | Voltage - Input [Min] | Voltage - Input [Max] | Applications | Power (Watts) | Type | Current - Output 1 | Efficiency | Features | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Voltage - Isolation | Voltage - Output 1 | Size / Dimension [z] | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 20.8 A  | 92 %  | Universal Input  | 180 mm  | 39.5 mm  | 107 mm  | 1.56 in  | 7.09 in  | 4.21 in  | 4000 V  | 24 V  | ||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 13.8 A  | 92 %  | Universal Input  | 102 mm  | 180 mm  | 4000 V  | 36 V  | 1.46 "  | 37 mm  | 7.1 "  | 4 "  | ||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 13.8 A  | 92 %  | Universal Input  | 102 mm  | 180 mm  | 4000 V  | 36 V  | 1.46 "  | 37 mm  | 7.1 "  | 4 "  | ||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 10.4 A  | 92 %  | Universal Input  | 180 mm  | 39.5 mm  | 107 mm  | 1.56 in  | 7.09 in  | 4.21 in  | 4000 V  | 48 V  | ||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 10.4 A  | 92 %  | Universal Input  | 102 mm  | 180 mm  | 4000 V  | 48 V  | 1.46 "  | 37 mm  | 7.1 "  | 4 "  | ||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 500 W  | Enclosed  | 13.8 A  | 92 %  | Universal Input  | 4000 V  | 36 V  | ||||||||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 13.8 A  | 92 %  | Universal Input  | 180 mm  | 39.5 mm  | 107 mm  | 1.56 in  | 7.09 in  | 4.21 in  | 4000 V  | 36 V  | ||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 13.8 A  | 92 %  | Universal Input  | 180 mm  | 39.5 mm  | 107 mm  | 1.56 in  | 7.09 in  | 4.21 in  | 4000 V  | 36 V  | ||||
TDK-LAMBDA  | 70 °C  | 0 °C  | 1  | Chassis Mount  | 90 VAC  | 264 VAC  | ITE (Commercial)  Medical  | 250 W  500 W  | Open Frame  | 10.4 A  | 92 %  | Universal Input  | 102 mm  | 180 mm  | 4000 V  | 48 V  | 1.46 "  | 37 mm  | 7.1 "  | 4 "  |