MBC150 Series
Manufacturer: Bel Fuse Inc.
AC/DC CONVERTER 5V 110/150W
| Part | Minimum Load Required | Efficiency | Mounting Type | Type | Voltage - Output 1 | Power (Watts) | Current - Output 1 | Size / Dimension Width | Size / Dimension Length | Size / Dimension Height | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Operating Temperature (Max) | Operating Temperature (Min) | Number of Outputs | Features | Applications | Voltage - Isolation |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 5 V | 110 W 150 W | 16 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 48 V | 110 W 150 W | 2.08 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 12 V | 110 W 150 W | 8.33 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 48 V | 110 W 150 W | 2.08 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 5 V | 110 W 150 W | 16 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 24 V | 110 W 150 W | 4.17 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 12 V | 110 W 150 W | 8.33 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 48 V | 110 W 150 W | 2.08 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 24 V | 110 W 150 W | 4.17 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |
Bel Fuse Inc. | No | 86 % | Chassis Mount | Open Frame | 15 V | 110 W 150 W | 6.67 A | 2 in | 4 in | 1.32 in | 90 V | 264 V | 70 °C | -20 °C | 1 | Adjustable Output DC Input Capable Standby Output Universal Input | Medical | 5900 Vrms |