| Part | Internal Switch(s) | Frequency - Switching (Min) | Frequency - Switching (Max) | Package Leads | Package Name | Mounting Type | Operating Temperature (Min) | Operating Temperature (Max) | Fault Protection | Voltage - Breakdown | Output Isolation | Duty Cycle | Power (Watts) | Topology | Package Features | Package Length | Package Width |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 6 Leads | 7-SSIP eSIP-7C | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 725 V | Isolated | 64 % | 59 W | Flyback | |||
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 6 Leads | 7-SSIP eSIP-7C | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 650 V | Isolated | 64 % | 47 W | Flyback | |||
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 6 Leads | 7-SSIP eSIP-7C | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 650 V | Isolated | 64 % | 59 W | Flyback | |||
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 6 Leads | 7-SSIP eSIP-7C | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 650 V | Isolated | 64 % | 35 W | Flyback | |||
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 6 Leads | 7-SSIP eSIP-7C | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 650 V | Isolated | 64 % | 153 W | Flyback | |||
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 12-SDIP eDIP-12 | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 650 V | Isolated | 64 % | 47 W | Flyback | 11 Leads Exposed Pad | 0.412 in | 10.46 mm | |
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 6 Leads | 7-SSIP eSIP-7C | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 725 V | Isolated | 64 % | 47 W | Flyback | |||
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 12-SDIP eDIP-12 | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 725 V | Isolated | 64 % | 25 W | Flyback | 11 Leads Exposed Pad | 0.412 in | 10.46 mm | |
POWER INTEGRATIONS | Yes | 120 kHz | 136 kHz | 6 Leads | 7-SSIP eSIP-7C | Through Hole | -40 °C | 150 °C | Current Limiting Over Load Over Temperature Over Voltage Short Circuit | 650 V | Isolated | 64 % | 117 W | Flyback |