Catalog
Switching Power Supplies 604.8W 48V 12.6A Med
Switching Power Supplies 604.8W 48V 12.6A Med
Switching Power Supplies 604.8W 48V 12.6A Med
| Part | Voltage - Input [Min] | Voltage - Input [Max] | Type | Mounting Type | Features | Power (Watts) | Number of Outputs | Current - Output 1 | Size / Dimension [z] | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [y] | Minimum Load Required | Efficiency | Approval Agency | Applications | Operating Temperature [Min] | Operating Temperature [Max] | Standard Number | Voltage - Isolation | Voltage - Output 1 | Power (Watts) | Size / Dimension [z] | Size / Dimension [y] | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDK-LAMBDA  | 85 VAC  | 265 VAC  | Enclosed  | Chassis Mount  | Adjustable Output  Remote On/Off  Remote Sense  Standby Output  Universal Input  | 401 W  600 W  | 1  | 33.4 A  | 1.67 "  | 6.18 "  | 3.35 "  | 157 mm  | 42.5 mm  | 85 mm  | 96 %  | CE  | ITE (Commercial)  Medical  | -20 °C  | 70 °C  | 60601-1  60950-1  62368-1  | 4000 V  | 12 V  | ||||
TDK-LAMBDA  | 85 VAC  | 265 VAC  | Enclosed  | Chassis Mount  | Adjustable Output  Remote On/Off  Remote Sense  Standby Output  Universal Input  | 401 W  600 W  | 1  | 21.1 A  | 1.67 "  | 6.18 "  | 3.35 "  | 157 mm  | 42.5 mm  | 85 mm  | 96 %  | CE  | ITE (Commercial)  Medical  | -20 °C  | 70 °C  | 60601-1  60950-1  62368-1  | 4000 V  | 19 V  | ||||
TDK-LAMBDA  | 85 VAC  | 265 VAC  | Enclosed  | Chassis Mount  | Adjustable Output  Remote On/Off  Remote Sense  Standby Output  Universal Input  | 403 W  | 1  | 8.4 A  | 1.67 "  | 6.18 "  | 3.35 "  | 157 mm  | 42.5 mm  | 85 mm  | 96 %  | CE  | ITE (Commercial)  Medical  | -20 °C  | 70 °C  | 60601-1  60950-1  62368-1  | 4000 V  | 48 V  | 605 W  | |||
TDK-LAMBDA  | 85 VAC  | 265 VAC  | Enclosed  | Chassis Mount  | Adjustable Output  Remote On/Off  Remote Sense  Standby Output  Universal Input  | 400 W  | 1  | 12.5 A  | 1.67 "  | 6.18 "  | 3.35 "  | 157 mm  | 42.5 mm  | 85 mm  | 96 %  | CE  | ITE (Commercial)  Medical  | -20 °C  | 70 °C  | 60601-1  60950-1  62368-1  | 4000 V  | 32 V  | 602 W  | |||
TDK-LAMBDA  | 85 VAC  | 265 VAC  | Open Frame  | Chassis Mount  | Remote On/Off  Remote Sense  Standby Output  Universal Input  | 401 W  600 W  | 1  | 33.4 A  | 127 mm  | 96 %  | CE  | ITE (Commercial)  Medical  | -20 °C  | 70 °C  | 60601-1  60950-1  62368-1  | 4000 V  | 12 V  | 1.34 in  34 mm  | 3 "  76.2 mm  | |||||||
TDK-LAMBDA  | 85 VAC  | 265 VAC  | Enclosed  | Chassis Mount  | Adjustable Output  Remote On/Off  Remote Sense  Standby Output  Universal Input  | 400 W  | 1  | 14.3 A  | 1.67 "  | 6.18 "  | 3.35 "  | 157 mm  | 42.5 mm  | 85 mm  | 96 %  | CE  | ITE (Commercial)  Medical  | -20 °C  | 70 °C  | 60601-1  60950-1  62368-1  | 4000 V  | 28 V  | 602 W  | |||
TDK-LAMBDA  | 85 VAC  | 265 VAC  | Enclosed  | Chassis Mount  | Adjustable Output  Remote On/Off  Remote Sense  Standby Output  Universal Input  | 400 W  600 W  | 1  | 11.1 A  | 1.67 "  | 6.18 "  | 3.35 "  | 157 mm  | 42.5 mm  | 85 mm  | 96 %  | CE  | ITE (Commercial)  Medical  | -20 °C  | 70 °C  | 60601-1  60950-1  62368-1  | 4000 V  | 36 V  |