MBC40 Series
Manufacturer: Bel Fuse Inc.
AC/DC CONVERTER 12V 40W
| Part | Minimum Load Required | Size / Dimension Length | Size / Dimension Width | Size / Dimension Height | Efficiency | Features | Number of Outputs | Voltage - Output 1 | Applications | Mounting Type | Type | Operating Temperature (Max) | Operating Temperature (Min) | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Power (Watts) | Current - Output 1 | Voltage - Isolation | Current - Output 3 | Voltage - Output 3 | Voltage - Output 2 | Current - Output 2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 1 | 12 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 3.5 A | 4242 V | ||||
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 3 | 5.2 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 6 A | 4242 V | 500 mA | -14.8 V | 14.6 V | 1.5 A |
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 1 | 5.1 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 8 A | 4242 V | ||||
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 3 | 5.2 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 6 A | 4242 V | 500 mA | -12.8 V | 24 V | 1 A |
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 1 | 5.1 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 8 A | 4242 V | ||||
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 3 | 5.2 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 6 A | 4242 V | 500 mA | -14.8 V | 14.6 V | 1.5 A |
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 1 | 15 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 2.7 A | 4242 V | ||||
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 1 | 48 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 830 mA | 4242 V | ||||
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 1 | 24 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 1.7 A | 4242 V | ||||
Bel Fuse Inc. | No | 4 in | 2 in | 1.2 in | 85 % | Adjustable Output Remote Sense Standby Output Universal Input | 1 | 15 V | Medical | Chassis Mount | Open Frame | 70 °C | -20 °C | 90 V | 264 V | 40 W | 2.7 A | 4242 V |