ULP275 Series
Manufacturer: Bel Fuse Inc.
AC/DC CONVERTER 58V 160W
| Part | Voltage - Output 1 | Current - Output 1 | Mounting Type | Number of Outputs | Efficiency | Operating Temperature (Max) | Operating Temperature (Min) | Type | Size / Dimension Length | Size / Dimension Height | Size / Dimension Width | Applications | Features | Minimum Load Required | Power (Watts) | Voltage - Isolation | Voltage - Input (AC) Minimum | Voltage - Input | Voltage - Input (AC) Maximum | Approval Agency | For Use With/Related Products | Accessory Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bel Fuse Inc. | 58 V | 2.76 A | Chassis Mount | 1 | 92 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | No | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | 58 V | 2.76 A | Chassis Mount | 1 | 92 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3.5 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |||
Bel Fuse Inc. | 58 V | 2.76 A | Chassis Mount | 1 | 92 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3.5 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | No | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | 15 V | 10.66 A | Chassis Mount | 1 | 88 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3.5 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | No | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | ||
Bel Fuse Inc. | ULP275 Series | Cover Assembly | ||||||||||||||||||||
Bel Fuse Inc. | 12 V | 13.33 A | Chassis Mount | 1 | 88 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |||
Bel Fuse Inc. | 24 V | 6.67 A | Chassis Mount | 1 | 90 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |||
Bel Fuse Inc. | 58 V | 2.76 A | Chassis Mount | 1 | 92 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |||
Bel Fuse Inc. | 15 V | 10.66 A | Chassis Mount | 1 | 88 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3.5 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL | |||
Bel Fuse Inc. | 48 V | 3.33 A | Chassis Mount | 1 | 92 % | 70 °C | -40 °C | Open Frame | 5 in | 0.75 in | 3.5 in | ITE (Commercial) | Adjustable Output PFC Standby Output Universal Input | No | 160 W 275 W | 3 kV | 80 V | 390 VDC | 264 V | CB CE cUL NEMKO UL |