RP30-FW Series
Manufacturer: Recom Power
ISOLATED DC/DC CONVERTERS - THROUGH HOLE 30W DC/DC 1.6KV REG 4:1 18-75IN +/-5OUT
| Part | Control Features | Efficiency | Features | Applications | Size / Dimension Width | Size / Dimension Length | Size / Dimension Height | Voltage - Isolation | Mounting Type | Operating Temperature (Min) | Operating Temperature (Max) | Power (Watts) | Voltage - Output 2 | Type | Package / Case | Voltage - Input (Max) | Current - Output (Max) | Voltage - Input (Min) | Voltage - Output 1 | Number of Outputs |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recom Power | Active High Enable | 88 % | OCP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | -5 V | Isolated Module | 6-DIP Module | 75 V | 3 A | 18 V | 5 V | 2 |
Recom Power | Active High Enable | 91 % | OCP OTP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | Isolated Module | 6-DIP Module | 75 V | 2 A | 18 V | 15 V | 1 | |
Recom Power | Active Low Enable | 88 % | OCP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | -12 V | Isolated Module | 6-DIP Module | 75 V | 1.25 A | 18 V | 12 V | 2 |
Recom Power | Active Low Enable | 89 % | OCP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | Isolated Module | 6-DIP Module | 36 V | 2 A | 9 V | 15 V | 1 | |
Recom Power | Active High Enable | 87 % | OCP OTP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | -15 V | Isolated Module | 6-DIP Module | 36 V | 1 A | 9 V | 15 V | 2 |
Recom Power | Active High Enable | 89 % | OCP OTP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | Isolated Module | 6-DIP Module | 36 V | 2.5 A | 9 V | 12 V | 1 | |
Recom Power | Active High Enable | 91 % | OCP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | Isolated Module | 6-DIP Module | 75 V | 2 A | 18 V | 15 V | 1 | |
Recom Power | Active Low Enable | 89 % | OCP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | Isolated Module | 6-DIP Module | 36 V | 2 A | 9 V | 15 V | 1 | |
Recom Power | Active Low Enable | 88 % | OCP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | -5 V | Isolated Module | 6-DIP Module | 36 V | 3 A | 9 V | 5 V | 2 |
Recom Power | Active High Enable | 88 % | OCP OVP Remote On/Off SCP | ITE (Commercial) | 1 in | 2 in | 0.4 in | 1.6 kV | Through Hole | -40 °C | 85 °C | 30 W | -5 V | Isolated Module | 6-DIP Module | 36 V | 3 A | 9 V | 5 V | 2 |