VF-S320 Series
Manufacturer: CUI Inc.
AC/DC CONVERTER 54V 320W
| Part | Mounting Type | Voltage - Isolation | Approval Agency | Efficiency | Voltage - Input (Range 2) Minimum | Voltage - Input (Range 1) Maximum | Voltage - Input (Range 2) Maximum | Voltage - Input (Range 1) Minimum | Applications | Operating Temperature (Max) | Operating Temperature (Min) | Standard Number | Number of Outputs | Type | Features | Current - Output 1 | Power (Watts) | Voltage - Output 1 | Size / Dimension Length | Size / Dimension Height | Size / Dimension Width | Minimum Load Required |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Open Frame | Adjustable Output PFC Universal Input | 3.33 A | 320 W | 54 V | 6 in | 1.5 in | 4 in | |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class A 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Enclosed | Adjustable Output PFC Universal Input | 13.33 A | 320 W | 24 V | 7 in | 1.6 in | 4 in | |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 60950-1 61000-3-2 61000-3-3 62368-1 | 1 | Enclosed | Adjustable Output PFC Standby Output | 17.78 A | 320 W | 18 V | 7 in | 1.55 in | 4 in | Yes |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Enclosed | Adjustable Output PFC Standby Output | 13.33 A | 320 W | 24 V | 7 in | 1.55 in | 4 in | Yes |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Enclosed | Adjustable Output PFC | 8.89 A | 320 W | 36 V | 7 in | 1.6 in | 4 in | |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Open Frame | Adjustable Output PFC Universal Input | 3.75 A | 320 W | 48 V | 6 in | 1.5 in | 4 in | |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Open Frame | Adjustable Output PFC Universal Input | 10 A | 320 W | 18 V | 6 in | 1.5 in | 4 in | |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Open Frame | Adjustable Output PFC Universal Input | 32 A | 320 W | 9 V | 6 in | 1.5 in | 4 in | |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class A 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Enclosed | Adjustable Output PFC Universal Input | 6.67 A | 320 W | 48 V | 7 in | 1.6 in | 4 in | |
CUI Inc. | Chassis Mount | 3 kV | CB Scheme EN IEC SIQ TUV UL | 83 % | 180 VAC | 132 V | 264 VAC | 90 VAC | ITE (Commercial) | 70 °C | 0 °C | 55024 55032 Class B 61000-3-2 61000-3-3 62368-1 | 1 | Enclosed | Adjustable Output PFC Universal Input | 17.78 A | 320 W | 18 V | 7 in | 1.6 in | 4 in |