GRN-110 Series
Manufacturer: Integrated Power Designs
GRN-110-3002 OVP CH
| Part | Voltage - Input (AC) Minimum | Voltage - Input (AC) Maximum | Approval Agency | Number of Outputs | Applications | Operating Temperature (Max) | Operating Temperature (Min) | Standard Number | Voltage - Output 1 | Voltage - Output 2 | Size / Dimension Length | Size / Dimension Height | Size / Dimension Width | Current - Output 1 | Current - Output 3 | Type | Current - Output 2 | Power (Watts) | Voltage - Output 3 | Features | Efficiency | Mounting Type | Minimum Load Required | Voltage - Output 4 | Current - Output 4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 3 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | 15 V | 5.25 in | 1.5 in | 3.25 in | 12 A | 3 A | Chassis | 3 A | 150 W | -15 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | ||
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 3 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | 12 V | 5.25 in | 1.5 in | 3.25 in | 12 A | 3 A | Chassis | 3 A | 132 W | -12 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | ||
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 4 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | 24 V | 5.25 in | 1.5 in | 3.25 in | 10 A | 2 A | Chassis | 2 A | 110 W | 12 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | -12 V | 2 A |
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 4 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | 24 V | 5.25 in | 1.5 in | 3.25 in | 10 A | 2 A | Enclosed | 2 A | 110 W | 15 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | -15 V | 2 A |
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 4 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | 24 V | 5.25 in | 1.5 in | 3.25 in | 10 A | 2 A | Enclosed | 2 A | 110 W | 12 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | -12 V | 2 A |
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 3 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | 12 V | 5.25 in | 1.5 in | 3.25 in | 12 A | 3 A | Chassis | 3 A | 110 W | -12 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | ||
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 4 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 3.3 V | 5 V | 5.25 in | 1.5 in | 3.25 in | 10 A | 2 A | Chassis | 5 A | 110 W | 12 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | -12 V | 2 A |
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 1 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 12 V | 5.25 in | 1.5 in | 3.25 in | 9.2 A | Enclosed | 110 W | Adjustable Output Remote Sense Universal Input | 87 % | Chassis Mount | No | ||||||
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 4 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | -5 V | 5.25 in | 1.5 in | 3.25 in | 10 A | 2 A | Chassis | 5 A | 123 W | 12 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No | -12 V | 2 A |
Integrated Power Designs | 85 VAC | 264 V | CE cURus TUV UKCA | 3 | ITE (Commercial) Medical | 70 °C | 0 °C | 60601-1 62368-1 | 5 V | 12 V | 5.25 in | 1.5 in | 3.25 in | 12 A | 3 A | Enclosed | 3 A | 132 W | -12 V | Adjustable Output Remote Sense Universal Input | 85 % | Chassis Mount | No |