RACM60-K/OF Series
Manufacturer: Recom Power
AC/DC OPEN FRAME POWER SUPPLY (PSU), 120 TO 370VDC, MEDICAL, 1 OUTPUT, 40 W, 80V AC TO 264V AC
| Part | Efficiency | Type | Voltage - Output 1 | Standard Number | Size / Dimension Height | Size / Dimension Length | Size / Dimension Width | Power (Watts) | Features | Applications | Voltage - Isolation | Number of Outputs | Approval Agency | Voltage - Input (DC) Minimum | Voltage - Input (DC) Maximum | Voltage - Input (AC) Maximum | Voltage - Input (AC) Minimum | Current - Output 1 | Operating Temperature (Max) | Operating Temperature (Min) | Mounting Type | Minimum Load Required | Package Leads | Package Name | Current - Output (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recom Power | 89 % | Open Frame | 5 V | 60335-1 60601-1 62368-1 | 1.24 in | 3.09 in | 2.09 in | 40 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 8 A | 85 °C | -40 °C | Chassis Mount | No | |||
Recom Power | 90 % | Open Frame | 24 V | 60335-1 60601-1 62368-1 | 1.24 in | 3.09 in | 2.09 in | 60 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 2.5 A | 85 °C | -40 °C | Chassis Mount | No | |||
Recom Power | 90 % | Open Frame | 12 V | 60335-1 60601-1 62368-1 | 1.24 in | 4 in | 2.09 in | 60 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 5 A | 85 °C | -40 °C | Chassis Mount | No | |||
Recom Power | 89 % | Open Frame | 5 V | 60335-1 60601-1 62368-1 | 1.24 in | 3.09 in | 2.09 in | 40 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 8 A | 85 °C | -40 °C | Chassis Mount | ||||
Recom Power | 90 % | Open Frame | 24 V | 60335-1 60601-1 62368-1 | 1.24 in | 3.09 in | 2.09 in | 60 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 2.5 A | 85 °C | -40 °C | Chassis Mount | No | |||
Recom Power | 90 % | Open Frame | 12 V | 60335-1 60601-1 62368-1 | 1.24 in | 3.09 in | 2.09 in | 60 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 5 A | 85 °C | -40 °C | Chassis Mount | No | |||
Recom Power | 90 % | Open Frame | 12 V | 1.39 in | 3.09 in | 2.09 in | 60 W | Universal Input | Household Appliances ITE (Commercial) Medical | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 85 °C | -40 °C | Through Hole | 6 Leads | 7-DIP Module | 5 A | ||||
Recom Power | 90 % | Open Frame | 48 V | 60335-1 60601-1 62368-1 | 1.24 in | 3.09 in | 2.09 in | 60 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 1.25 A | 85 °C | -40 °C | Chassis Mount | No | |||
Recom Power | 90 % | Open Frame | 24 V | 60335-1 60601-1 62368-1 | 1.24 in | 4 in | 2.09 in | 60 W | Universal Input | Household Appliances ITE (Commercial) Medical | 4000 Vpk | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 2.5 A | 85 °C | -40 °C | Chassis Mount | No | |||
Recom Power | 89 % | Open Frame | 5 V | 1.39 in | 3.09 in | 2.09 in | 40 W | Universal Input | Household Appliances ITE (Commercial) Medical | 1 | CB CE cURus | 120 V | 370 V | 264 V | 80 V | 85 °C | -40 °C | Through Hole | 6 Leads | 7-DIP Module | 8 A |