Technical Specifications

Parameters and characteristics for this part

SpecificationCX10S-BHBBBB-P-A-DK00000
ApplicationsITE (Commercial), Medical
Approval AgencyIEC, UL, EN, CSA
Current - Output 115 A
Current - Output 2 [custom]6 A
Current - Output 33 A
Current - Output 415 A
Current - Output 515 A
Current - Output 615 A
Efficiency93 %
FeaturesStandby Output, Remote Sense, Adjustable Output, Universal Input, PMBus™
Minimum Load RequiredFalse
Mounting TypeChassis Mount
Number of Outputs7
Operating Temperature [Max]85 °C
Operating Temperature [Min]-40 °C
Power (Watts)1 kW
Size / Dimension [x]10.22 "
Size / Dimension [x]259.5 mm
Size / Dimension [y]6.46 "
Size / Dimension [y]164 mm
Size / Dimension [z]1.6 "
Size / Dimension [z]40.6 mm
Standard Number60950-1, 60601-1, 62368-1
TypeEnclosed
Voltage - Isolation4000 V
Voltage - Output 112 V
Voltage - Output 25 V
Voltage - Output 324 V
Voltage - Output 412 V
Voltage - Output 512 V
Voltage - Output 612 V

CX10S Series

...
PartOperating Temperature [Max]Operating Temperature [Min]Standard NumberFeaturesSize / Dimension [y]Size / Dimension [x]Size / Dimension [z]Size / Dimension [x]Size / Dimension [y]Size / Dimension [z]Current - Output 4Current - Output 1Mounting TypeCurrent - Output 6Approval AgencyTypeVoltage - IsolationVoltage - Output 6Number of OutputsVoltage - Output 2Voltage - Output 1Voltage - Output 3Current - Output 3Voltage - Output 5 [custom]Power (Watts)ApplicationsMinimum Load RequiredEfficiencyCurrent - Output 2Current - Output 5Voltage - Output 4Voltage - Output 5Height [z]Height [z]Number of Positions
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
6 A
4.17 A
Chassis Mount
4.17 A
CSA
EN
IEC
UL
Enclosed
4000 V
48 V
6
12 V
48 V
48 V
4.17 A
24 V
880 W
ITE (Commercial)
Medical
93 %
15 A
3 A
5 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
8.3 A
6 A
Chassis Mount
3 A
CSA
EN
IEC
UL
Enclosed
4000 V
24 V
8
24 V
5 V
12 V
15 A
980 W
ITE (Commercial)
Medical
93 %
3 A
6 A
24 V
5 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
4.17 A
4.17 A
Chassis Mount
6 A
CSA
EN
IEC
UL
Enclosed
4000 V
5 V
7
48 V
48 V
48 V
4.17 A
1 kW
ITE (Commercial)
Medical
93 %
4.17 A
4.17 A
48 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
6.5 "
10 in
254 mm
165.1 mm
CSA
EN
IEC
UL
Medical
4000 V
1 kW
93 %
1 in
25.4 mm
6
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
3 A
3 A
Chassis Mount
3 A
CSA
EN
IEC
UL
Enclosed
4000 V
24 V
11
24 V
24 V
5 V
6 A
24 V
780 W
ITE (Commercial)
Medical
93 %
3 A
3 A
24 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
6 A
4.17 A
Chassis Mount
4.17 A
CSA
EN
IEC
UL
Enclosed
4000 V
48 V
7
48 V
48 V
48 V
4.17 A
24 V
1 kW
ITE (Commercial)
Medical
93 %
4.17 A
3 A
5 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
6 A
6 A
Chassis Mount
4.17 A
CSA
EN
IEC
UL
Enclosed
4000 V
48 V
9
24 V
5 V
48 V
4.17 A
24 V
900 W
ITE (Commercial)
Medical
93 %
3 A
3 A
5 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
3 A
3 A
Chassis Mount
3 A
CSA
EN
IEC
UL
Enclosed
4000 V
24 V
12
24 V
24 V
5 V
6 A
660 W
ITE (Commercial)
Medical
93 %
3 A
6 A
24 V
5 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
8.3 A
15 A
Chassis Mount
15 A
CSA
EN
IEC
UL
Enclosed
4000 V
12 V
6
24 V
12 V
24 V
8.3 A
1 kW
ITE (Commercial)
Medical
93 %
8.3 A
15 A
24 V
12 V
EXCELSYS / Advanced Energy
85 °C
-40 °C
60601-1
60950-1
62368-1
Adjustable Output
PMBus™
Remote Sense
Standby Output
Universal Input
6.46 "
10.22 "
1.6 "
259.5 mm
164 mm
40.6 mm
3 A
6 A
Chassis Mount
3 A
CSA
EN
IEC
UL
Enclosed
4000 V
24 V
12
24 V
5 V
5 V
6 A
620 W
ITE (Commercial)
Medical
93 %
3 A
6 A
24 V
5 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

DistributorPackageQuantity$

Description

General part information

CX10S Series

Enclosed AC DC Converters 7 Output 12V 5V 24V 12V 85 ~ 264 VAC Input

Documents

Technical documentation and resources